Study of refrigeration system with minichannel condenser using R1234ze, R134a, R152a, R600a, R290 and mixture of R290/R600a (50/50)

Author:

Bhatkar Vijay W1ORCID,Sur Anirban2,Kumar Ramesh2ORCID

Affiliation:

1. Department of Mechanical Engineering, Marathwada Mitra Mandal's College of Engineering, Pune, India

2. Department of Mechanical Engineering, Symbiosis Institute of Technology, Symbiosis International, Pune, India

Abstract

A versatile vapor compression refrigeration (VCR) system is designed, developed and manufactured for testing different alternative refrigerants to R134a. The refrigerants such as R1234ze, R152a, R600a, R290 and mixture of R290/R600a (50/50) refrigerants are tested with an aluminum minichannel condenser which is designed for R134a. All the refrigerants are experimented for condensation temperature varying from 40 to 55°C while evaporation temperature varying from −10 to +15°C for every condensing temperature. The performance parameters like volumetric refrigerating capacity, actual work consumption of compressor, coefficient of performance (COP) and condenser capacity are compared for different alternative refrigerants. Aluminum minichannel condenser has reduced condensing temperature by 2–3°C with an increase in COP by 10%. The ratio of volumetric refrigerant capacities for R152a, R1234ze, R600a, R290 and HC mixture of R290/R600a (50/50) with respect to R134a are found to be 1.296, 1.143, 0.736, 1.749 and 1.067, respectively which is useful to select specific compressor. The ratio of compressor work for R600a, R290, HC mixture of R290/R600a, R152a and R1234ze with respect to R134a are found to be 1.81, 1.812, 1.867, 1.6 and 1.1, respectively. The ratios of condenser capacity of R600a, R290, HC mixture of R290/R600a, R152a and R1234ze with respect to R134a are found to be 1.914, 2.061, 1.939, 1.65 and 1.064, respectively. It is found that COP of R152a, R600a and R1234ze are larger by 11.53, 5.38 and 27% over R134a whereas COP of R290/R600a (50/50) and R290 are decreased by 0.75% and 14.23% over R134a, respectively. The exergy loss analysis for VCR system components is carried out at condensing temperature of 44°C while evaporating temperature ranging from −10 to +15°C for all the refrigerants and found that total exergy loss is more for R600a among all refrigerants.

Funder

Dassault Systèmes La Fondation

Publisher

SAGE Publications

Subject

Industrial and Manufacturing Engineering,Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3