Thermal–hydraulic analysis of a solar air heater fitted with a wire-roughened absorber plate

Author:

Madhukeshwara Nanjundappa1ORCID,Alhadhrami A2,Alzahrani Hassan A H3ORCID,Prasanna B H4ORCID

Affiliation:

1. Department of Mechanical Engineering, Jain Institute of Technology, Davanagere 577 003, India

2. Department of Chemistry, College of Science, Taif University, P. O. Box 11099, Taif 21944, Saudi Arabia

3. Department of Chemistry, College of Science and Arts at Khulais, University of Jeddah, P. O. Box 355, Jeddah, Saudi Arabia

4. Department of Chemistry, Jain Institute of Technology, Davanagere 577 003, India

Abstract

This study is to evaluate heat transmission and friction in a rectangular solar air heater with a V-shaped wire rib roughness on the absorber plate that operates in fully formed turbulent flow. Additionally, studies are performed to generate prediction equations for the average friction factor, Stanton number, and efficiency index. The Reynolds number [Formula: see text]–[Formula: see text], angle of attack [Formula: see text]20[Formula: see text]–90[Formula: see text]), relative roughness pitch [Formula: see text]–[Formula: see text], relative roughness height [Formula: see text]–[Formula: see text], and the aspect ratio [Formula: see text]–[Formula: see text] was varied. The efficiency index [Formula: see text] is commonly employed as a thermo-hydraulic performance metric. It is computed as [Formula: see text]. The wire roughness and airflow parameters [Formula: see text] are optimized to maximize heat transfer while retaining minimal friction losses. On the basis of resemblance criteria, average Stanton numbers, average Nusselt numbers, and even average friction factors are derived. The results are compared to those obtained with a smooth absorber duct under similar airflow circumstances in order to assess the increase in heat transfer coefficient and friction factor. The [Formula: see text], and [Formula: see text] have a significant influence on thermo–hydraulic performance, according to these studies. With [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text], the optimal configuration geometry for wire roughness and solar air heater duct is identified.

Publisher

SAGE Publications

Subject

Industrial and Manufacturing Engineering,Mechanical Engineering

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3