Abstract

This study is about the fog on the windshields of passenger buses because it makes it hard for drivers to see, which is dangerous. The goal of the research is to come up with an effective way to spread the produced mist. According to the study, the air duct design, which is connected to the car’s defroster and defrosting system by Kraft hoses, has to be upgraded. The analysis identifies areas in which the current air duct design might be enhanced and then makes design modifications to create a superior design. By conducting climatic chamber experiments on a vehicle equipped with the first air duct design and tracking the actual air velocity values at the nozzle tips, the success of the new technique is assessed. The boundary conditions for the analysis are the observed values. The study involves the utilization of a commercially available software package to conduct investigations on both the original and modified air duct designs. The software package employs a k-ε turbulence model that is known to produce reliable results. The data demonstrate that the adjustments made in light of the comparison produced beneficial effects. The maximum air velocities were increased by 23%, while the pressure loss values of the left and right fans were reduced by 2.5% and 2.9%, respectively, due to the modification of the air duct. Significant energy was saved because of the decrease in fan pressure loss, which led to decreases in the power consumption of the left and right fans of 4.2% and 4.7%, respectively. This comparison shows that the newly built air ducts actually increased the flow rate at the system’s fan outlets by 40%.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3