Affiliation:
1. Polish Academy of Science-IPPT ul. Swietokrzyska 21
00-049-Warsaw, Poland
2. Oak Ridge National Laboratory Building Thermal Envelope Systems & Materials Group P.O. Box 2008 Oak Ridge, TN 37831-6092
Abstract
The idea of the "thermally equivalent wall," the plane mul tilayer structure of dynamic characteristics similar to those for complex structure, in which three-dimensional heat flow occurs, is presented. The notion of structure factors is introduced and the conditions they impose on response factors are derived. Examples of complex structures are analyzed. For the same examples, thermally equivalent walls were generated. Response factors for the nominal complex structures were compared with the response factors for equivalent walls. The good accuracy in reproducing the response factors indicates that the "thermally equivalent wall" may be used as a sub stitute of a wall with thermal bridges in building design energy simulations.
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献