Effect of side guide marks of ultrasound transducer on the success rate of ultrasound transducer-guided radial artery puncture: A randomized trial

Author:

Yao Jie1,Hao Shuai2,Zhou Chen3,Quan ZheFeng2ORCID

Affiliation:

1. Department of Anesthesiology, First Affiliated Hospital of Hebei North University, Zhangjiakou, Hebei, China

2. Department of Anesthesiology, Beijing YouAn Hospital, Capital Medical University, Beijing, China

3. Department of Zoology and Physiology, University of Wyoming, Laramie, Wyoming, USA

Abstract

Background: Compared with blind technique, ultrasound (US) transducer-guided technique for radial artery puncture can improve the success rate. However, difficulty in handling US transducer-guided technology is a key limitation to its wider use. The aim of the study was to explore the effect of guide marks on the side of US transducer on the success rate of US transducer-guided radial artery puncture. Methods: In this parallel-group trial, 127 patients undergoing elective liver cancer resection and splenectomy under general anesthesia were randomly allocated to the traditional group or the Intervention group. The traditional group used the conventional US transducer-guided radial artery puncture technology, while the Intervention group used the US transducer-guided radial artery puncture technology with the guide marks on the side of the US transducer probe. The primary observation index was success rate of radial artery cannulation at the first attempt; the secondary observation indices were failure rate of cannulation, location time, and total time for successful cannulation. Results: The successful rate of cannulation in the Intervention group (59 out of 63, 93.6%) was greater than that in the traditional group (50 out of 64, 78.1%, p = 0.01). The posterior wall puncture rate in the Intervention group was lower than that in the traditional group (11.1% vs 32.8%, p = 0.005). The location time in the Intervention group was longer than that in the traditional group (20.1 ± 3.8 vs 16.6 ± 4.0 s, p < .001), while the total cannulation time was significantly shorter (20.7 ± 4.3 vs 32.4 ± 7.4 s, p < 0.001). Conclusion: Using guide marks on the side of US transducer can help improve success rate of US transducer-guided radial artery puncture at the first attempt and reduce the risk of puncture-related complications.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3