Quantitative physical examination indicators to detect patients with stenosis at a high risk of thrombosis at hemodialysis vascular access sites: A retrospective case–control study

Author:

Chen Matt Chiung-Yu1ORCID,Weng Mei-Jui2,Chao Lee-Hua1,Wu Misoso Yi-Wen3,Liu Yi-Chun4,Chi Wen-Che4

Affiliation:

1. Department of Interventional Radiology, Yuan’s General Hospital, Kaohsiung

2. Department of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung

3. Department of Interventional Nursing, Yuan’s General Hospital, Kaohsiung

4. Department of Nephrology, Yuan’s General Hospital, Kaohsiung

Abstract

Background: Quantitative physical examination (PE) indicators, including palpable pulsatility length and outflow scores, can be used to quantify stenosis severity at hemodialysis vascular access sites. It is known that the risk of high-shear-related thrombosis is increased when the minimal luminal diameter (MLD) of stenosis decreases. At present, MLD is measured using sonography or angiography. This study sought to determine the relationship between quantitative PE indicators and MLD and report their diagnostic performance in detecting patients with stenosis at a high risk of thrombosis. Methods: We performed a retrospective case–control study using routinely collected data. We used the post-stenosis palpable pulsatility length (sPPL) and pulse-and-thrill based outflow score to assess the severity of AVF inflow and outflow stenosis, respectively. We recorded paired quantitative PE indicators and MLD before and after angioplasty in patients enrolled over a 4-month period. Results: A total of 249 paired PE indicators and MLD measurements were obtained from 163 patients. A receiver operating characteristic curve analysis showed that an MLD cutoff value of <1.55 mm and an MLD of <1.95 mm discriminated sPPL = 0 and PESOS (physical examination significant outflow stenosis)/1− of the outflow score, respectively, from all other measurements, with the area under the curve values of 0.8922 and 0.9618, respectively. With sPPL = 0 and PESOS/1− of the outflow score as diagnostic tools to detect inflow stenosis with an MLD of ⩽1.5 mm and outflow stenosis with an MLD of ⩽1.9 mm at vascular access sites, sensitivity = 86.00% and 88.46%; specificity = 97.67% and 92.11%; positive predictive values of 97.73% and 92.00% and negative predictive values of 85.71% and 88.61%, respectively, were observed. Conclusions: Our preliminary results showed that physical examination can potentially be a diagnostic tool in detecting patients with stenosis who are at a high risk of thrombosis at hemodialysis vascular access sites with high diagnostic accuracy.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3