Using CorMatrix for partial and complete (re)construction of arteriovenous fistulas in haemodialysis patients: (Re)construction of arteriovenous fistulas with CorMatrix

Author:

Leskovar Bostjan1,Furlan Tjasa1,Poznic Simona1,Hrastelj Miran2,Adamlje Anton3

Affiliation:

1. Department of Internal Medicine, Trbovlje General Hospital, Trbovlje, Slovenia

2. Department of Surgery, Trbovlje General Hospital, Trbovlje, Slovenia

3. Department of Haemodialysis, Trbovlje General Hospital, Trbovlje, Slovenia

Abstract

Introduction: CorMatrix is an acellular extracellular matrix that acts as a biological scaffold and remodels into site-specific tissue. We used it for the (re)construction of arteriovenous fistulas. Methods: In this prospective pilot case study, we used CorMatrix in six patients. We included patients who required vascular access reconstruction due to thrombosis of unsalvageable arteriovenous fistulas, patients with high-flow arteriovenous fistulas and patients with microvasculature in which autologous arteriovenous fistulas did not mature, requiring reconstruction with a graft. We sutured the CorMatrix plate into a tubular shape and then constructed arterial and venous anastomoses. Results: There were no periprocedural complications, CorMatrix-related infections, bleeding or limb swelling after the procedures. CorMatrix was first punctured after 8–10 weeks. In five patients, a percutaneous angioplasty due to CorMatrix stenosis was performed; in one patient, a stent was placed due to refractory stenosis. We observed eight thromboses during the observation period (four in one patient). Perianastomotic stenosis of CorMatrix and interdialytic hypotension were the causes of the thrombosis in five patients, cephalic arch stenosis in two patients and thromboembolism to the brachial artery and arteriovenous fistula in one patient. Thrombendarteriectomy was successful in 87.5% of patients, and one patient required arteriovenous fistula reconstruction. After a median observation period of 12.5 (range 4–23) months, all arteriovenous fistulas were patent, with a median brachial artery flow of 1450 (range 700–1700) mL/min. Conclusion: Arteriovenous fistula (re)construction with CorMatrix seems to be feasible and safe, with a relatively high incidence of neointimal hyperplasia, predominantly at venous anastomoses, but additional clinical studies are needed.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3