Difficult cannulation of hemodialysis arteriovenous fistula – Role of imaging in access management (DICAF STUDY)

Author:

Behera Manas Ranjan1ORCID,John Elenjickal Elias1ORCID,Thomas Athul1,David Vinoi George1,Alexander Suceena1ORCID,Mohapatra Anjali1,Valson Anna T1,Jacob Shibu1,Kakde Shailesh1,Koshy Pradeep Mathew1,Rajan Gautam1,Varughese Santosh1ORCID

Affiliation:

1. Department of Nephrology, Christian Medical College, Vellore, TN, India

Abstract

Background: Difficulty in cannulation of arteriovenous fistula (AVF) can lead to inadequate dialysis, transient to permanent loss of access and increases dependency on bridging catheters. This study aimed to analyze the causes for difficult fistula cannulation, using various imaging modalities. Methodology: This was a retrospective single-center observational study conducted between October 2017 and June 2018. Patients whose fistulae were difficult to cannulate were initially evaluated by physical examination followed by doppler ultrasonography or/and fistulogram as necessary. The patients were divided into two groups that is, primary difficult cannulation (within first three months of creation of fistula) or secondary difficult cannulation (after three months). Results: We encountered difficult cannulation in 43 patients. About 60% were primary difficult cannulations. Most common causes for difficulty in cannulation were cannulation zone (CZ) stenosis (23.3%), immature fistula (20.9%), outflow stenosis (18.6%), inflow stenosis (11.6%), anatomical abnormalities (11.6%), outflow plus CZ stenosis (9.3%) and inflow plus CZ stenosis (4.7%). Among patients with primary difficult cannulation, immature fistula (34.6%) was the most common cause, whereas CZ stenosis (47.1%) was the most common etiology for secondary difficult cannulation. Edema leading to difficult cannulation was found in 12 patients (27.9%), all of which was due to central vein stenosis. Cannulation resulted in hematoma, fistula thrombosis, failure of fistula and pseudoaneurysm in 83.7%, 27.9%, 16.3%, and 2.3% of cases respectively. Bridging temporary dialysis catheter placement was required in 67.4% patients. Ultrasound doppler had lower diagnostic value when compared to fistulogram (71.4% vs 93.9%, p = 0.014). Conclusion: Difficulty in cannulating the arteriovenous fistula is a common problem in hemodialysis patients. We suggest that patients whose fistulae are difficult to cannulate should undergo early radiological evaluation to decrease catheter dependency and access failure.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3