Comparative intervention assessing a catheter stabilization device on peripheral intravenous line loss

Author:

Wilson Gabriela M1ORCID,Winsett Rebecca P2,Modi Bhumika3,Jia Ru3,Patton Terilea3,Silberberg Debra3

Affiliation:

1. Multi-Interprofessional Center for Health Informatics, The University of Texas at Arlington, Arlington, TX, USA

2. Retired Nurse Scientist, St. Vincent Evansville, Evansville IN, USA

3. Former Health Informatics student, University of Southern Indiana, Evansville, IN, USA

Abstract

Background: Short peripheral intravenous catheters are the most common invasive procedure used to deliver medications, blood products, and fluids to patients, and failure has the potential to impact the quality of care. Methods: This study compared IVs stabilized with current transparent film dressing to those using an engineered stabilization device. The first phase of the study evaluated documentation; data from patient records were found less than optimal but most complete for securement and removal, the two fields most critical to the study. The second phase measured IV dwell time, restart rates, and time between IV loss and restarts. Results: Although there were no statistically significant differences in restarts, the IV dwell time was longer when the engineered device was in place, helping to extend the life of the IV and prevent interruption of care. In the absence of data on the cost of infections and other complications, the use of an engineered device increased the cost of IV starts. Conclusions: Adding an engineered stabilization device increases the cost of peripheral IV starts, but contributes to reducing IV restarts and preventing IV complications due to destabilized IVs. Although there were no statistically significant differences in restarts, the IV dwell time was longer when the device was in place, helping to extend the life of the IV and prevent interruption of care. Complete and accurate documentation and improved quality depended upon the ability to abstract unit-level data, which is vital for capturing the appropriate healthcare indicators. Clinical nurses must be involved in the decision-making regarding health records and operability at the unit level.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3