Safe and effective HeRO graft placement: Technique and results

Author:

Illig Karl A1ORCID,London Mark J2,Aruny John2,Ross John R2ORCID

Affiliation:

1. FLOW Vascular Institute, Houston, TX, USA

2. Dialysis Access Institute, Regional Medical Center of Orangeburg and Calhoun Counties, Charleston, SC, USA

Abstract

Objectives: Hemodialysis Reliable Outflow (HeRO) grafts are used when venous outflow is inadequate to support conventional access. These have been perceived as complex to implant and being associated with high risk. We have evolved a defined protocol for insertion that minimizes morbidity and maximizes efficiency. Methods: Our protocol includes staged intravenous access versus HeRO graft placement, reverse Trendelenburg positioning, subcutaneous access of the deep portion of the existing catheter, use of a stiff wire placed within the inferior vena cava, dilation of the tract to 8 mm, device lubrication, all insertion procedures directly visualized, and use of immediate access conduits with SuperHeRO connector. Results: From 7/1/18 to 8/13/19, 55 HeRO grafts were placed at our institution following this protocol, average age 58 ± 15 (26–86) years (mean ± SD, range). 53 (96%) had had prior ipsilateral central access (13 by means of “inside out” 2 weeks prior) the other two had on-table access. Mean procedure time was 70 ± 26 (38–148) min. Excluding seven “complex” cases, procedure time for our first 20 cases using this protocol was 72 ± 29 min, while that of the last 28 was 62 ± 18 min ( p < 0.05). One patient suffered acute CHF after unclamping; despite reclamping and ligation he died on POD 3 (mortality rate 2%). 71% were done as outpatients, and 47 of 53 evaluable patients (89%) had their grafts used within 36 h for dialysis. Only one patient (2%) has had an infection within 30 days (cellulitis). At a mean followup of 95 ± 105 (maximum 383) days, three additional patients have had graft infections requiring excision, for a total infection rate of 5/53 (9%). Conclusions: Our results suggest that HeRO graft placement can be performed with minimal morbidity and mortality on an outpatient basis. Short-term infection rates are low and 89% of patients have their grafts immediately accessed and are discharged without a catheter.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3