Malposition of the central venous catheter secondary to accessory hemiazygos vein variant

Author:

Hajeh Haidar1ORCID,Garcia Austin2,Mishra Shikha1,Radicic Kasey1

Affiliation:

1. UCLA - David Geffen School of Medicine - Kern Medical Center, Bakersfield, CA, USA

2. Ross University School of Medicine, Miramar, FL, USA

Abstract

A 36-year-old female with sickle cell disease presented with sickle cell pain crisis. After failure to establish peripheral venous access, an internal jugular central venous catheter (CVC) was placed. Confirmation of internal jugular cannulation was performed with bedside ultrasound. A confirmatory chest X-ray revealed an unusual position of the catheter, taking a course inferiorly, making a loop and remaining on the left side of the mediastinum. A lateral view was done and revealed that the catheter passed inferiorly through the internal jugular vein then posteriorly and inferiorly giving the looped appearance. This is better delineated on a sagittal view CT scan showing the tip of the catheter terminating in the accessory hemiazygos vein. This unusual course is due to a variant of the accessory hemiazygos vein which is connected to the left superior intercostal vein. This creates a lower resistance pathway for the CVC which passes from the internal jugular vein, down the left superior intercostal vein (instead of the left brachiocephalic vein) and into the accessory hemiazygos vein. Discussion: The correct tip placement of an internal jugular CVC terminates in the superior vena cava just above the cardiac silhouette. In 1%–2% of individuals, a connection between the accessory hemiazygos and the left superior intercostal vein is present. Rare cases are discovered incidentally during CVC placement. The diameter of the accessory hemiazygos vein is less than half of that of the superior vena cava. The catheter should not be used as central venous access and removal is recommended. Malpositioning of central catheters is unpredictable but can be easily avoided by using intraprocedural methods to confirm tip position. Such modalities include intracavitary ECG or ultrasound with agitated saline injection as described in the SIC (Safe Insertion of Centrally Inserted Central Catheters) protocol.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3