Peripheral intravenous catheters in hospitalized patients: Practice, Dwell times, and factors impacting the dwell times: A single center retrospective study

Author:

Tripathi Sandeep1ORCID,Gladfelter Taylor2

Affiliation:

1. Pediatric Critical Care, OSF Saint Francis Medical Centre Peoria, IL, USA

2. Healthcare Analytics, OSF Saint Francis Medical Centre, Peoria, IL, USA

Abstract

Background: Despite being the most common hospital procedure, limited information is available on the peripheral intravenous (PIV) catheter insertion practices. This study was designed to evaluate the contemporary PIV insertion practice (all age groups), and to identify the patient and device-related factors influencing the dwell times (<18 years). Methods: Single Center Retrospective study. Patients of all age groups admitted to the hospital for >4 midnights, from 01/2015 to 12/2019. Data extracted by automated EMR audits. Variables included patient demographics, number of PIVs inserted, PIV size, location, dwell time, and length of stay. Standard comparative analysis, including multivariable linear regression for dwell time performed for patients <18 years. Results: A total of 44,198 (39,341 (89%) adults and 4857 (11%) children) PIVs on unique patients met study criteria, with mean duration of 2.8 ± 2.4 days in children and 2.6 ± 1.3 days in adults ( p < 0.001). Pediatric PIV had more dwell time variation, with a higher proportion lasting <1-day and also >2 SD of the age-specific mean, compared to adults. Adults had significantly higher number of PIVs placed/week compared to children. The failure rate for PIV was 56% in children and 76% in adults ( p < 0.001). 1 out of 5 adults required >5 PIV/admission. Forty-five percent of children requiring only one PIV versus 21.8% of seniors. Discharge department, body part, and PIV size were independently associated with the dwell duration in children. No PIV size, however, had an independent increase in dwell duration over the reference of the 24 Ga cannula in children. PIVs placed in ante cubital vein and upper arm had dwell duration 26% and 20% longer than PIVs placed in the hand. Conclusions: The failure rate of PIV is high, and patients are subjected to multiple insertions during hospitalization. Hospital unit, body part, and PIV size are associated with the dwell duration in children.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3