Functioning tailor-made 3D-printed vascular graft for hemodialysis

Author:

Li Ming-Chia12,Chang Pu-Yuan34,Luo Huai-Rou1,Chang Ling-Yuan1,Lin Chuan-Yi5,Yang Chih-Yu23467ORCID,Lee Oscar Kuang-Sheng3789,Wu Lee Yan-Hwa12,Tarng Der-Cherng2347

Affiliation:

1. Department of Biological Science and Technology, College of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu

2. Center for Intelligent Drug Systems and Smart Bio-devices (IDS2B), Hsinchu

3. Institute of Clinical Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei

4. Division of Nephrology, Department of Medicine, Taipei Veterans General Hospital, Taipei

5. Taiwan Instrument Research Center, National Applied Research Laboratories, Hsinchu

6. Division of Clinical Toxicology and Occupational Medicine, Department of Medicine, Taipei Veterans General Hospital, Taipei

7. Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei

8. Stem Cell Research Center, National Yang Ming Chiao Tung University, Taipei

9. Department of Orthopedic Surgery, China Medical University Hospital, Taichung

Abstract

Background: The two ends of arteriovenous graft (AVG) are anastomosed to the upper limb vessels by surgery for hemodialysis therapy. However, the size of upper limb vessels varies to a large extent among different individuals. Methods: According to the shape and size of neck vessels quantified from the preoperative computed tomography angiographic scan, the ethylene-vinyl acetate (EVA)-based AVG was produced in H-shape by the three-dimensional (3D) printer and then sterilized. This study investigated the function of this novel 3D-printed AVG in vitro and in vivo. Results: This 3D-printed AVG can be implanted in the rabbit’s common carotid artery and common jugular vein with ease and functions in vivo. The surgical procedure was quick, and no suture was required. The blood loss was minimal, and no hematoma was noted at least 1 week after the surgery. The blood flow velocity within the implanted AVG was 14.9 ± 3.7 cm/s. Additionally, the in vitro characterization experiments demonstrated that this EVA-based biomaterial is biocompatible and possesses a superior recovery property than ePTFE after hemodialysis needle cannulation. Conclusions: Through the 3D printing technology, the EVA-based AVG can be tailor-made to fit the specific vessel size. This kind of 3D-printed AVG is functioning in vivo, and our results realize personalized vascular implants. Further large-animal studies are warranted to examine the long-term patency.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3