Peripheral intravenous cannulae in neonates: To splint or not?

Author:

Serane V Tiroumourougane1,Rajasekaran Rathnapratheep2ORCID,Vijayadevagaran Vijayasankar1,Kothendaraman Bhuvaneswari3

Affiliation:

1. Canvij Neonatal Services, A.G. Padmavati’s Hospital, Arumparthapuram, Pondicherry, India

2. Department of Pediatrics, Sri Venkateswara Medical College, Ariyur, Pondicherry, India

3. Department of Medicine, Indira Gandhi Medical College and Research Institute, Kathirkamam, Pondicherry, India

Abstract

Objective: To determine the effect of splint on the dwell time of peripheral intravenous cannula in neonates. Setting: Level II Neonatal Intensive Care Unit (NICU). Patients: Consecutive babies with presumed need of peripheral intravenous access of at least 24 h. Methods: Enrolled subjects were randomized to “splint” or “splint-less” group. Insertion site was cleaned with Isopropyl alcohol and 2% Chlorhexidine and peripheral intravenous catheter was inserted under strict asepsis. Insertion sites was examined regularly for occurrence of complication which necessitated removal of the catheter. Results: Out of 159 neonates, 80 were allotted to splint group and the rest to splint-less group. Mean dwell time of intravenous line in splint group was 27.68 ± 13.03 h which was significantly less than in splint-less group (32.87 ± 15.79 h, mean difference: 5.11 h, p value: 0.03). Subgroup analysis in preterms showed mean dwell time of 28.54 ± 14.86 h in splint group which was less than that of splint-less group (35.10 ± 16.24 h) ( p value: 0.03). No such difference was noted in the term neonates. Subgroup analysis for catheters put across joints does not show difference in mean dwell times between splint and splint-less groups. Multivariate regression analysis did not identify any variable which independently affected the outcome. Conclusion: Use of splint does not prolong the dwell time of the catheter and is probably harmful in some neonates.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3