New insertion support device assisted the accurate placement of tunneled cuffed catheter: First experience of 10 cases

Author:

Ohara Toshiaki12,Sakurama Kazufumi23,Hiramatsu Satoshi3,Karai Toshimasa4,Sato Toshiaki5,Nishina Yuta67

Affiliation:

1. Department of Pathology & Experimental Medicine, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan

2. Department of Gastroenterological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama, Japan

3. Department of Dialysis Access Center, Shigei Medical Research Hospital, Okayama, Japan

4. K.techno Corporation, Kurashiki, Japan

5. Specified Nonprofit Organization Medical Techno Okayama, Okayama, Japan

6. Research Core for Interdisciplinary Sciences, Okayama University, Okayama, Japan

7. Graduate School of Natural Science and Technology, Okayama University, Okayama, Japan

Abstract

Introduction: The tunneled cuffed catheter is used in hemodialysis patients for whom an arteriovenous fistula or arteriovenous graft is not suitable or for bridging usage of them. Accurate placement of a tunneled cuffed catheter is necessary for safe hemodialysis, but placement is sometimes difficult because of individual body differences. We developed a new device to support accurate placement of the tunneled cuffed catheter. In this study, we report our first clinical experience of the device. Methods: We made the device by expanded polytetrafluoroethylene with some special processes. The processes enable it to maintain plasticity and temporary shape in the autoclaved condition. The device is laid on the surface of the patient’s body to mark the root of the catheter with a felt-tipped marker before catheterization. That enables us to know the accurate catheter root and tunneled cuffed catheter exit site on the body surface. Ten patients underwent tunneled cuffed catheter insertion according to the marking. Case description: The mean age was 71.3 ± 12.8 years. The tunneled cuffed catheter was safely placed according to the marking in all patients, and all catheter tips were placed in the right atrium. The mean verification tip location difference before and after catheterization was 0.70 ± 0.48 cm. This result indicated that the device could assist in inserting a catheter accurately within an error of 1.18 cm. The tunneled cuffed catheters were patent in all the cases, without replacement and complications until the end of bridging use or during the observation period. Conclusion: Our newly developed insertion support device enhances safety and prevents catheter waste during replacement.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3