Scale ultrasound-guided radial artery cannulation in infant: A randomized controlled trial

Author:

Yang Fei1ORCID,Li Shangyingying1,Chen Hang1,Jiang Rui1,Wang Xuanqin1,Wang Weiping1,Shi Yuan1,Liu Lifei1,Guo Hongjie1,Ye Mao1,Tu Shengfen1,Wang Qiang1,Wang Hong1

Affiliation:

1. Chongqing Key Laboratory of Pediatrics, Department of Anesthesiology, Ministry of Education Key Laboratory of Child Development and Disorders, National Clinical Research Center for Child Health and Disorders, China International Science and Technology Cooperation Base of Child Development and Critical Disorders, Children’s Hospital of Chongqing Medical University, Chongqing, China

Abstract

Background: Cannulation of the radial artery can be extremely challenging in infants. Scale ultrasound can provide accurate arterial location and guidance for operators. We hypothesized that scale ultrasound helps increase the initial success rate of radial artery cannulation in this population. Method: Seventy-six infants aged 0–3 months who needed arterial puncture after general anesthesia were randomly divided into two groups (1:1 ratio): the scale ultrasound group and the traditional ultrasound group. The primary endpoints were the success rate of the first attempt and the total success rate of arterial cannulation. The secondary endpoints were the time during arterial puncture and the incidence of vascular complications. Results: The success rate of the first attempt and the total success rate of arterial cannulation were 92.1% (35/38) versus 50% (19/38) and 100% (38/38) versus 86.8% (33/38) in the scale ultrasound and traditional ultrasound group ( p < 0.005), respectively. The median time to ultrasound location, needle entry into the radial artery, and successful cannulation in the scale ultrasound group were significantly shorter than those in the traditional ultrasound group: 10 (8.0, 17.2) s, 15 (11.7, 20) s, and 65 (53.8, 78.5) s vs 30 (26.5, 43.5) s, 35 (23, 51) s, and 224.5 (123.5, 356) s ( p < 0.001), respectively. The incidence of hematoma was higher in the traditional group ( p < 0.005). Conclusions: Scale ultrasound-guided radial arterial cannulation can significantly improved initial success rate and overall success rate, shorten puncture time in infant, compared with that achieved with the use of traditional ultrasound guidance.

Funder

natural science foundation of chongqing

national outstanding youth science fund project of national natural science foundation of china

the National Key Clinical Program

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献