Drug-coated balloon for early recurrent arteriovenous fistula dysfunction

Author:

Hsin Chun-Hsien1ORCID,Yang Hsuan-Tzu1,Feng Pin-Chao1,Su Ta-Wei1,Yu Sheng-Yueh1,Ko Po-Jen1ORCID

Affiliation:

1. Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Taoyuan, Linkou

Abstract

Objective: To report the efficacy and safety of a drug-coated balloon (Ranger, Boston Scientific) in patients with dysfunctional autogenous arteriovenous fistula. Methods: In this investigator-initiated, prospective observational cohort study, 25 participants with dysfunctional arteriovenous fistula were enrolled from January 2018 to June 2019. The drug-coated balloon was applied after successful vessel preparation by high-pressure balloon angioplasty. The primary endpoint was the target lesion primary patency rate at 6 months. The secondary outcome included anatomical and clinical success rate, postoperative major adverse events within 30 days, and the target lesion primary patency rate at 12 months. Statistical analysis of the data was performed. The χ test or Fisher’s exact test was used for analyzing categorical variables, and continuous variables were analyzed using Student’s t-test. Also, Kaplan-Meier analysis was used to evaluate the target lesion primary patency days with the log-rank test. Results: At 6 months, the target lesion primary patency rate was 68% in the drug-coated balloon treatment group. The anatomical and clinical success rates were 100%. One patient had thrombosed access 10 days after the index procedure, and two died of cardiovascular events 4 months after the operation. Subgroup analysis showed that the early recurrent stenosis group had non-inferior mean drug-coated balloon primary patency days (less than 90 days after prior percutaneous angioplasty, n = 10) compared with the late recurrence group (prior PTA patency days more than 90 days, n = 10), 179.3 ± 102.9 versus 257.1 ± 71 days ( p = 0.153). DCB angioplasty had significant improvement in primary patency days for early recurrent stenosis (67.7 ± 19.3 vs 179.3 ± 102.9, p < 0.001). Conclusions: The results demonstrated the appliance of Ranger DCB in stenotic AVFs is a safe and effective treatment modality, especially for early recurrent AVF stenosis.

Funder

Boston Scientific Corporation

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3