Abstract

Background: Haemodialysis requires a vascular access, most commonly an arteriovenous fistula, which many patients consider a lifeline. It is important to select a cannulation technique assuring a low number of complications. Buttonhole cannulation using sharp needles is a common technique, but information is scarce regarding its long-term consequences. In this study, we aimed to investigate whether the choice of cannulation technique – buttonhole with sharp or blunt needles – affected the development of arteriovenous fistula complications. Methods: We retrospectively reviewed medical records from 2008 to 2015, including 49 patients and 52 AVFs. We compared the complications in patients cannulated with the buttonhole technique using sharp needles versus blunt needles. Results: The recorded complications were grouped into major and everyday complications. Although major complications were not significantly more frequent with sharp needles than with blunt needles, there were higher numbers of bleedings between dialyses with sharp needles. In addition, everyday complications (e.g. infiltration, oozing and large scabs) were significantly more frequent with sharp needles than blunt needles. Moreover, patients with multiple everyday complications had a higher probability of experiencing a major complication with sharp needles. Conclusion: More frequent cannulation with blunt needles can reduce the rate of everyday complications. This practice may additionally reduce patient suffering and the incidence of major complications.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Reference21 articles.

1. Patients’ Perspectives on Hemodialysis Vascular Access: A Systematic Review of Qualitative Studies

2. Parisotto MT, Pancirova J (eds). Vascular access cannulation and care a nursing best practice guide for arteriovenous fistula. Lucerne: European Dialysis and Transplant Nurse Association/European Renal Care Association (EDTNA/ERCA), 2014, p. 38.

3. A RANDOMISED CONTROLLED TRIAL OF BUTTONHOLE CANNULATION FOR THE PREVENTION OF FISTULA ACCESS COMPLICATIONS

4. Patients’ Perspectives of Constant-Site (Buttonhole) Cannulation for Haemodialysis Access

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3