USE of IMplanting the Biotronik PassEo-18 Lux drug coated balloon to treat failing haemodialysis arteRiovenous FIstulas and grafts (SEMPER FI Study)

Author:

Ho Tze Gek1ORCID,Tang Tjun Yip2ORCID,Yap Charyl Jia Qi3ORCID,Yap Hao Yun3,Chan Shaun Wen Yang1,Leong Chuo Ren1,Chan Dexter Yak Seng1

Affiliation:

1. Department of General Surgery, Khoo Teck Puat Hospital, Singapore, Singapore

2. The Vascular & Endovascular Clinic, Gleneagles Medical Centre, Singapore, Singapore

3. Department of Vascular Surgery, Singapore General Hospital, Singapore, Singapore

Abstract

Background: Plain old balloon angioplasty has been the mainstay of treatment for arteriovenous fistula (AVF) stenoses. Recent studies suggest that drug coated balloons (DCB) may significantly reduce re-intervention rates on native and recurrent lesions. The Passeo-18 Lux DCB (Biotronik AG, Buelach, Switzerland) is packaged with a 3.0 µg/mm2 dose of paclitaxel. The hypothesis is that its use provides better target lesion primary patency (TLPP), primary assisted patency (PP), secondary patency (SP) rates and reduces the number of visits for re-intervention in a cohort of patients with stenotic AVF and arteriovenous grafts (AVGs). Methods: The USE of IMplanting the Biotronik PassEo-18 Lux DCB to treat failing haemodialysis arteRiovenous FIstulas and grafts trial (SEMPER FI) was a prospective double-centre, multi-investigator, non-consecutive, non-blinded single-arm study investigating the efficacy and safety of the Passeo-18 Lux DCB in patients with stenotic AVF/AVG lesions between January 2021 and January 2022. Patient demographics, clinical characteristics, vascular access history, operative indications, details and outcomes were collected prospectively. TLPP, circuit access primary patency (CAP), PP, SP and deaths 6- and 12-months post-intervention were studied. Results: Ninety-one patients with 110 lesions were recruited across the two centres. 62.6% ( n = 57) were male with a median age of 63.5 years (SD = 10.5). 62.6% ( n = 57) were taking anti-platelets. Eighty-five AVFs and six AVGs were treated. 60% ( n = 54) of AVFs intervened were radiocephalic. 52.7% ( n = 58) of targeted lesions were juxta-anastomotic stenosis (JAS) and one-third ( n = 33) at the AVF/AVG outflow. 70.9% ( n = 78) of lesions were recurrent. Median time from last intervention was 219 days. 78% of target lesions ( n = 85) and circuits ( n = 70) were patent at 6-months, of which 96.7% ( n = 87) of those requiring assisted intervention were patent. Conclusion: This study shows that the Passeo-18 Lux DCB can be an effective and safe tool in the treatment of failing haemodialysis AVFs/AVGs.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3