Intracavitary electrocardiography-guided positioning of central vascular access device can spare unnecessary ionizing radiation exposure in pediatric patients

Author:

Raffaele Alessandro1ORCID,Segal Aviad1,Romano Piero1,Vatta Fabrizio1,Boghen Stella2,Bonetti Federico2,Parigi Gian Battista1,Avolio Luigi1

Affiliation:

1. Department of Pediatric Surgery, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy

2. Department of Pediatric Hematology and Oncology, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy

Abstract

Background: Most hospital protocols—including those of our own institute—require the use of radiography to validate tip position in every central vascular access device placement. This study evaluated whether unnecessary ionizing radiation exposure could be spared in the pediatric population when intracavitary electrocardiography is used to guide catheter placement. Material and methods: Retrospective study of intracavitary electrocardiography-guided central vascular access device placements in our pediatric surgery department between 2013 and 2018. We evaluated the operating time, success in positioning the catheter, and accuracy of final tip position. We also assayed the effects of catheter type and of catheter access point on operating time, success, accuracy, and complications. We applied the chi-square test for statistical analysis. Results: In total, 622 interventions of central vascular access device placements were evaluated; 340 intracavitary electrocardiography-guided central vascular access device placements were included in the study. The electrocardiography method successfully positioned the tip of the catheter in 316/340 (92.94%) of placements. Where intracavitary electrocardiography placement was successful, radiography confirmed accuracy of tip position in 314/316 (99.41%) of placements. Conclusion: When electrocardiography-guided positioning is uneventful and a valid P-Wave pattern is seen, postprocedure radiograph imaging for verification is unnecessary. Any effort should be made to upgrade hospital policies according to evidences and newest guidelines to spare pediatric patients harmful exposure to radiation by limiting the use of radiography only to selected cases.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3