Analysis of tip malposition and correction of peripherally inserted central catheters under ultrasound-guidance: 5-year outcomes from a single center

Author:

Jang Eunju1ORCID,Son Soo Mi1,Moon Ki-yoon1,Lee Seunghoon1,Han Hong Seok1,Park Sun Cheol1,Kim Jang Yong1,Yun Sang Seob1ORCID

Affiliation:

1. Division of Vascular and Transplant Surgery, Department of Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seocho-gu, Seoul, Republic of Korea

Abstract

Background: Peripherally inserted central catheter (PICC) has become a common procedure. Although ultrasound (US)-guidance has improved success rates, a small percentage of malposition is inevitable. The purpose of our study is to evaluate malposition rates of US-guided bedside PICC catheter insertion, and the clinical factors associated with malposition. Methods: This is a retrospective cohort study evaluating 5981 patients who had undergone ultrasound-guided bedside PICC placement from January 2017 to December 2021 at a single tertiary center. Final tip location was confirmed on chest radiograph. Results: Patients were categorized into optimal, suboptimal, and malposition groups according to final tip location. 4866 cases (81.7%) showed optimal tip position, 790 (13.3%) were suboptimal, and 299 (5.0%) were malpositioned. Logistic regression analysis identified six variables associated with tip malposition; height (odds ratio (OR) 1.044; 95% confidence interval (CI), 1.028–1.061; p < 0.001), body mass index (BMI) (OR 1.051; 95% CI, 1.017–1.087; p = 0.003), prior failure at accessing peripheral intravenous (IV) access (OR 1.718; 95% CI, 1.215–2.428; p = 0.002), side of the arm (OR 3.467; 95% CI, 2.457–4.891; p < 0.001), length of the catheter (OR 0.763; 95% CI, 0.734–0.794; p < 0.001), and number of previous central catheter insertions (OR 1.069; 95% CI, 1.004–1.140; p = 0.038). Malpositioned catheters were corrected by either bedside repositioning, bedside reinsertion, fluoroscopic reinsertion, switching to jugular catheters or catheter removal. No patient related factors were significantly associated with malposition or success of reposition. Conclusion: US-guidance can help reduce catheter malposition during bedside PICC insertion. Patients with risk factors such as multiple previous central vein insertions, failed peripheral line insertions, left arm insertion, or high BMI should undergo thorough sonographic evaluation of the arm vessels to prevent malposition.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3