Transthoracic echocardiography as bedside technique to verify tip location of central venous catheters in patients with atrial arrhythmia

Author:

Iacobone Emanuele1ORCID,Elisei Daniele1,Gattari Diego1,Carbone Luigi1,Capozzoli Giuseppe2

Affiliation:

1. Department of Intensive Care and Anesthesia, Central Hospital of Macerata, Macerata, Italy

2. Department of Anesthesia, Central Hospital of Bolzano, Bolzano, Italy

Abstract

Introduction: Transthoracic echocardiography with bubble test is an accurate, reproducible, and safe technique to verify the location of the tip of the central venous catheter. The aim of this study is to confirm the effectiveness of this method for tip location in patients with atrial arrhythmia. Methods: Transthoracic echocardiography with bubble test was adopted as a method of tip location in patients with atrial arrhythmia requiring central venous catheter. If bubbles were evident in the right atrium in less than 2 s after simple saline injection, tip placement was assumed as correct. In cases of uncertain visualization of the bubble effect, the test was repeated injecting a saline–air mixture. Tip location was also assessed by post-procedural chest X-ray. Results: In 42 patients with no evident P-wave at the electrocardiography, we placed 34 centrally inserted central catheters and 8 peripherally inserted central catheters. Transthoracic echocardiography with bubble test detected two centrally inserted central catheter malpositions. In four patients with peripherally inserted central catheter, transthoracic echocardiography with bubble test was positive only when repeated with the saline–air mixture. When the transthoracic echocardiography was positive, the mean (±standard deviation) time for onset of the bubble effect was 0.89 ± 0.33 s in patients with centrally inserted central catheter and 1.1 ± 0.20 s in those with peripherally inserted central catheter; such time difference was not statistically significant (p > 0.05). Conclusion: Tip location of central venous catheter by transthoracic echocardiography with bubble test is feasible, safe, and accurate in patients with atrial arrhythmia. This method can also be applied in peripherally inserted central catheters; however, further studies may be needed to confirm its use in this type of catheters.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3