Resolution of high-output cardiac failure secondary to high flow radiocephalic fistula by precision banding under ultrasound guidance: A case report

Author:

Wan Ziming1,Mboya Vincent N1ORCID,Lai Qiquan1,Tu Bo2,Zhou Yu1,Chen Ling2,Chen Bo2

Affiliation:

1. Department of Nephrology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, P.R. China

2. Ultrasonography Department, The First Affiliated Hospital of Chongqing Medical University, Chongqing, P.R. China

Abstract

Background: The creation of dialysis shunt affects hemodynamic and cardiac function. High-output cardiac failure may occur if dialysis access volume flow is greater than 1500 to 2000 mls/min. To resolve symptoms of cardiac failure due to high flow dialysis shunt requires flow reduction procedure. We describe successful resolution of symptoms of heart failure due to excessive flow dialysis access by adopting precision banding, totally under vascular ultrasound guidance without angiography. Case: Hemodialysis adult patient uses the right arm radiocephalic fistula for 4 years. Recently, the patient presented with symptoms of high-output cardiac failure, including dyspnea, palpitations, fatigue, and orthopnea. The cardiac unit excluded all other causes of cardiac failure and referred the patient to our center for further evaluation. Ultrasonography revealed high blood volume flow measuring 3100 mls/min at brachial artery, marking high flow fistula and the underlying cause of cardiac failure. Juxta-anastomotic segment of fistula vein was identified; 3 mm diameter balloon was advanced to the juxta-anastomotic segment and maximally inflated. Two precision bandings were made on this segment, 1 to 2 cm apart with flow reduction to 691 mls/min. All steps of the procedure were done under ultrasound guidance without angiography. All symptoms were significantly alleviated immediately following the procedure. The patient was discharged after 48 h of monitoring. At 6 months, the patient was stable, no recurrence of high flow access, no signs or symptoms of cardiac failure, and the flow was 1119 mls/min. Conclusion: This case demonstrates that the precision banding procedure is feasible under ultrasound guidance, and the procedure is safe and effective in resolution of cardiac failure due to high flow radiocephalic fistula.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3