Arteriovenous fistula creation with VasQTM device: A feasibility study to reveal hemodynamic implications

Author:

Bozzetto Michela1ORCID,Soliveri Luca2,Poloni Sofia2ORCID,Brambilla Paolo3,Curtò Diego4,Condemi Giuseppina Carmela4,Cefalì Pietro5,Spina Irene5,Villa Alessandro6ORCID,Caroli Anna2,Remuzzi Andrea7ORCID

Affiliation:

1. Department of Engineering and Applied Sciences, University of Bergamo, Italy

2. Department of Biomedical Engineering - Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy

3. Diagnostic Radiology, Papa Giovanni XXIII Hospital, University of Milano-Bicocca, Milan, Italy

4. Unit of Nephrology and Dialysis, ASST Ospedale Papa Giovanni XXIII, Bergamo, Italy

5. Unit of Vascular Surgery, ASST Ospedale Papa Giovanni XXIII, Bergamo, Italy

6. Department of Renal Medicine, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy

7. Department of Management, Information and Production Engineering, University of Bergamo, Italy

Abstract

Background: Arteriovenous fistula (AVF) is the preferred vascular access (VA) for hemodialysis, but it is still affected by high non-maturation and early failure rates due to stenosis development. Increasing evidence suggests that the presence of turbulent-like flow may play a key role, therefore, to stabilize the flow in the venous segment, an external support device (VasQTM) has been designed. The aim of this study was to provide preliminary evidence of VasQTM impact on AVF hemodynamics as compared to AVFs created with conventional surgery. Methods: In this pilot single-center prospective randomized study six patients were enrolled, three in the VasQ group and three in the control group. Contrast-free magnetic resonance imaging (MRI) scans were acquired at 3 days, 3 months and 1 year after AVF surgery and were used to generate 3D patient-specific models. Computational fluid dynamic (CFD) simulations were performed using pimpleFoam, imposing patient-specific flow waveforms derived from ultrasound (US) examinations at the inlet of the proximal and distal artery, and a traction-free condition at the venous outflow. Morphologic and hemodynamic changes occurring over time were compared between VasQ and control AVFs. Results: Our MRI protocol provided high-quality images suitable for reliable segmentation and reconstruction of patient-specific 3D models of AVFs at all three timepoints in four out of six patients. The VasQTM device maintained the angle between the artery and the vein almost unchanged over time, with a more stable flow in the AVFs supported by the device. In contrast, one of the AVFs of the control group evolved to an extreme dilatation of the vein and highly disturbed flow, while the other developed a stenosis in the juxta-anastomotic region. Conclusions: This study demonstrated the feasibility of characterizing the morphological and hemodynamic changes occurring over time in AVFs created using the VasQTM device and provided preliminary evidence of the potential hemodynamic benefits of its use.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3