Reliability of cutaneous landmarks for the catheter length assessment during peripherally inserted central catheter insertion: A retrospective observational study

Author:

Elli Stefano1ORCID,Bellani Giacomo12,Cannizzo Luigi1,Giannini Luciano1,De Felippis Christian1,Vimercati Simona1,Madotto Fabiana2,Lucchini Alberto1ORCID

Affiliation:

1. Emergency Department and Intensive Care, University of Milano-Bicocca, A.S.S.T. Monza, San Gerardo Hospital, Monza, MB, Italy

2. University of Milano-Bicocca, Milano, Italy

Abstract

Introduction: Peripherally inserted central catheters are very common devices for short, medium and long-term therapies. Their performance is strictly dependent on the correct tip location, at the junction between the upper caval vein and the right atrium. It is very important to obtain an estimated measure of the catheter, in order to reach the cavo-atrial junction and optimize the catheter length. Estimated measures are often obtained using cutaneous landmarks. Objective: Evaluate the reliability of cutaneous landmark-based length estimation during catheter insertion. Identify any patient’s related factors that may affect cutaneous landmarks reliability. Methods: We used two distinct techniques and collected data about cutaneous landmark-based length estimation, electrocardiographic guided intravascular length, age, weight and height. We studied the reliability of possible correcting factors, balancing the error average by regression models, and we found and tested two different models of prediction. Results: A total number of 519 patients were studied. The average bias, between the two studied length assessment by cutaneous landmarks and electrocardiographic guided catheter length, were 3.77 ± 2.44 cm and 3.28 ± 2.57 cm, respectively. The analysed prediction models (deviance explained 43.5%, Akaike information criterion = 1313.67% and 43.4%, Akaike information criterion = 1313.92), fitted on the validation set, showed a root mean square error of 3.07 and 3.06. Conclusion: Landmark-based length estimation for preventive catheter length assessment seems to be unreliable, when associated with post-procedural tip location. They are useful for distal trimming catheters to optimize the ‘out of skin’ portion when associated with electrocardiographic tip location. Models identified for balancing bias are probably not useful.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3