PICC-PORT totally implantable vascular access device in breast cancer patients undergoing chemotherapy

Author:

Bertoglio Sergio12ORCID,Cafiero Ferdinando2,Meszaros Paolo3,Varaldo Emanuela12,Blondeaux Eva4,Molinelli Chiara4,Minuto Michele12

Affiliation:

1. Department of Surgical Sciences (DISC), University of Genova, Genova, Italy

2. General Surgery Unit 1, Department of Surgery, IRCCS Ospedale Policlinico San Martino, Genova, Italy

3. Breast Surgical Unit, Department of Surgery, IRCCS Ospedale Policlinico San Martino, Genova, Italy

4. Oncologia Medica Unit 2, Department of Medical Oncology, IRCCS Ospedale Policlinico San Martino, Genova, Italy

Abstract

Background and objectives: The increasing use of arm totally implantable vascular access devices for breast cancer patients who require chemotherapy has led to a greater risk of complications and failures and, in particular, to upper extremity deep vein thrombosis. This study aims to investigate the outcomes of the arm peripherally inserted central catheter-PORT technique in breast cancer patients. Methods: The peripherally inserted central catheter-PORT technique is an evolution of the standard arm-totally implantable vascular access device implant based on guided ultrasound venous access in the proximal third of the upper limb with subsequent placement of the reservoir at the middle third of the arm. A prospective study was conducted on 418 adult female breast cancer patients undergoing chemotherapy. The primary study outcome was peripherally inserted central catheter-PORT failure. Results: Median follow-up was 215 days. Complications occurred in 29 patients (6.9%) and failure resulting in removal of the device in 11 patients (2.6%). The main complication we observed was upper extremity deep vein thrombosis, 10 (2.4%); all patients were rescued by anticoagulant treatment without peripherally inserted central catheter-PORT removal. The main reason for removal was reservoir pocket infection: 4 (0.9%) with an infection rate of 0.012 per 1000 catheter days. Cumulative 1-year risk of failure was 3.6% (95% confidence interval, 1.3%–7.1%). With regard to the patients’ characteristics, body mass index <22.5 was the only significant risk for failure ( p = 0.027). Conclusion: The peripherally inserted central catheter-PORT is a safe vascular device for chemotherapy delivery that achieves similar clinical results as traditional long-term vascular access devices (peripherally inserted central catheter and arm totally implantable vascular access device, in particular) in breast cancer patients.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3