Purpose An arteriovenous fistula (AVF) is the first choice vascular access for hemodialysis. The AVF pathway can be seen as consisting of seven segments: proximal artery, distal artery, arterial collaterals, proximal vein, distal vein, venous collaterals, and the anastomosis. While most studies describe access complications without considering the impact of the anastomosis (7th segment), the present mathematical study investigated the hemodynamic impact of anastomosis size and angle on pressure drop and flow distribution. Methods A side-to-end AVF model was developed, consisting of an anastomosis with a given cross-sectional area (substudy 1) and angle (substudy 2). Starting from two reference cases (one for each substudy) with fixed flow distribution, pressure drop over the anastomosis was calculated for an arterial inflow in the range 600 to 1200 ml/min. The same reference cases, subsequently with fixed pressure boundary conditions, were further used to assess flow distribution over the proximal vein and distal artery. Results Pressure drop decreased with a larger anastomosis cross-sectional area and an angle wider than 43°, while it was almost stable for smaller angles. Although proximal arterial inflow increased for larger anastomosis areas, the overall flow distribution shifted almost totally to the proximal vein. When the anastomosis angle exceeded 58°, the proximal arterial inflow was not sufficient to deliver enough flow, leading to distal arterial flow reversal. Conclusion Despite the underestimation of the hemodynamic impact of the anastomosis size and angle in the literature, this study showed major influences on the pressure drop over the anastomosis and, with it, on flow distribution towards the arterial and venous outflow.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3