Central Vein Catheterization of Dialysis Patients with Real Time Ultrasound Guidance

Author:

Gallieni M.1

Affiliation:

1. Nephrology and Dialysis Unit, San Paolo Hospital, University Department Milan - Italy

Abstract

Internal jugular vein cannulation has become a routinary and clinically important aspect of medical care in critically ill patients. The landmark-guided technique usually affords rapid and easy vascular access, but it is not always successful and may be complicated by arterial puncture, hematoma, pneumothorax. A prospective, descriptive study is reported on the use and success of ultrasound-assisted central vein catheterization in dialysis patients who had an indication for internal jugular vein catheterization. Data were collected prospectively on number of punctures, needle passes, and success rates. Over a 6-year period, there were 220 attempts at internal jugular catheterization in 205 patients and ultrasound guidance was used in 210 of the 220 (95%) attempts. Incidences of successful puncture and cannulation using ultrasound were 100% (210 out of 210) and 99.5% (209 out of 210), respectively, compared with 80% (8 out of 10) and 80% (8 out of 10) in the landmark group. With the availability of the ultrasound device complication rates also improved markedly, suggesting that the ultrasound technique is an easily learned technique that rapidly produces an improvement over the external landmark method. First attempt success improved from 20% to 85%, carotid punctures decreased from 33% to 2.9% (6 out of 210). The patient population also included 32 patients with several high risk conditions, such as no visual or palpable landmarks, severe coagulopathies due to hepatic failure or excess of anticoagulation treatment. In these patients, cannulation was successful in 100% (32 out of 32) using ultrasound guidance. In 9 patients (9/195, 4.6%), preliminary ultrasound evaluation of the neck vessels failed to identify a right internal jugular vein suitable for cannulation, because of thrombosis or a small diameter of the vein. In all cases, the left internal jugular vein could be cannulated without difficulties. Our results confirm that ultrasound-guided cannulation of the internal jugular vein offers several advantages over the external landmarks technique: higher success rate in both vein puncture and catheter placement, lower complications, lower patient discomfort during the procedure because of a low number of needle passes. Ultrasound-assisted cannulation of the internal jugular vein may become the standard approach to dialysis catheter placement in the future.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3