Use of the helical SUPERA™ stent and Passeo-18 Lux™ drug-coated balloon to treat recurrent cephalic arch stenosis for dysfunctional brachiocephalic fistulas: 1 year results of the Arch V SUPERA-LUX study

Author:

Tang Tjun Yip12ORCID,Soon Shereen Xue Yun1ORCID,Yap Charyl Jia Qi1ORCID,Chan Sze Ling3,Tan Ru Yu4ORCID,Pang Suh Chien4,Choke Edward Tieng Chek5,Tan Chieh Suai4ORCID,Chong Tze Tec1

Affiliation:

1. Department of Vascular Surgery, Singapore General Hospital, Singapore, Singapore

2. Duke NUS Graduate Medical School, Singapore, Singapore

3. Health Services Research Center, SingHealth, Singapore, Singapore

4. Department of Renal Medicine, Singapore General Hospital, Singapore, Singapore

5. Department of General Surgery, Sengkang General Hospital, Singapore, Singapore

Abstract

Background: Aim of Arch V SUPERA-LUX was to evaluate the safety and efficacy of the combination therapy of SUPERA™ ( Abbott Vascular, Santa Clara, CA, USA) helical stent implantation and Passeo-18 Lux™ ( Biotronik Asia Pacific Pte Ltd, Singapore) drug coated balloon (DCB) elution to treat recurrent cephalic arch stenosis (CAS) in the setting of AV access dysfunction. Methods: Investigator-initiated, single-center, single-arm prospective pilot study of 20 end-stage renal failure Asian patients with a dysfunctional brachiocephalic fistula. All had symptomatic recurrent CAS within 6 months of prior intervention. The lesion was pre-dilated with a standard high-pressure balloon (Biotronik Passeo-35 HP balloon). The DCB (Passeo-18 Lux™) is subsequently inflated and the SUPERA™ stent deployed to sit 2 mm distal to the cephalic arch and covering the CAS but within the DCB zone. All patients were prescribed dual antiplatelet therapy for 3 months and followed up with Duplex ultrasound at 6- and 12-months. Results: There were 9 (45%) males and mean age was 67 ± 11.0 years. Mean time from prior procedure was 113 ± 68 days and main indication for reintervention was high venous pressure (9/20, 45%). Technical success was 100% and there were no peri-procedural complications related to either stent or DCB deployment. Target lesion primary patency at 6- and 12-months was 10/18 (55%) and 5/16 (31%), respectively. Mean time to target lesion re-intervention was 170 ± 82 days. Circuit access patency was 8/18 (44%) and 2/16 (13%) at 6- and 12-months respectively and mortality was 3/20 (15%) attributed to the patients’ underlying co-morbidities. Conclusion: Dual prong strategy of using SUPERA™ stenting and Passeo-18 Lux™ drug elution for recurrent CAS, although safe, was no more efficacious than conventional balloon angioplasty or stenting alone. Development of an intense inflammatory reaction within the stent led to reinterventions of a number of cases with suboptimal results.

Funder

Biotronik

Abbott Vascular

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3