Inadvertent intra-arterial catheterisation using ultrasound guidance and endocavitary electrocardiography in a paediatric patient

Author:

Musella Giuseppe1,Crespi Andrea1,Apostolou Garyfalia1,Azzari Serena1,Ambrosoli Andrea Luigi1ORCID

Affiliation:

1. Anesthesiology and ICU, ASST Sette Laghi, Varese, Lombardia, Italy

Abstract

Venous access in small infants is difficult and central venous catheter placed into the brachiocephalic vein is often the preferred approach. Ultrasound guided vein cannulation is standard practice and endocavitary electrocardiography is a reliable catheter tip location method. We report a not immediately recognised 2 month old case of inadvertent intra-arterial catheterisation with a 3 Fr – 8 cm catheter during right innominate vein cannulation under ultrasound guidance. Endocavitary electrocardiography showed an increased amplitude P wave with a low P/R wave ratio but further insertion of the catheter resulted in a reduction of the P wave amplitude. At ultrasound re-evaluation of the innominate vein, the catheter seemed to be inside the vessel into the proximal part of the vein, but distally appeared to surpass the vein to get into the brachiocephalic artery at the level of the bifurcation of the right common carotid artery and the right subclavian artery. Cardiac ultrasound from the suprasternal notch view identified the catheter into the aortic arch. Contrast-enhanced CT scan with 3D reconstruction confirmed the intra-arterial catheterisation and showed that the innominate vein was shifted and partially compressed but not transfixed by the catheter. The catheter was non-surgically removed uneventfully. During innominate vein cannulation the catheter cannot always be visualised into the distal tract of the vein and the maximal P wave may have a low P/R ratio; a chest X-ray can identify intra-arterial but false negative results are possible. We recommend always using a real time ultrasound tip navigation and location protocol, like the Neo-ECHOTIP protocol, to confirm the correct position of the guidewire and the catheter. If the catheter cannot be identified inside the venous system, we suggest systematically visualising the aortic arch from the suprasternal notch view and the aortic root from the parasternal view to identify arterial malposition.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3