Safety of bilateral arm pressure measurements in the diagnostic workup of dialysis-associated steal syndrome

Author:

Benfor Bright1ORCID,Bohle Kihoon2,Peden Eric K1ORCID

Affiliation:

1. Division of Vascular Surgery, Houston Methodist Debakey Heart and Vascular Center, Houston, TX, USA

2. School of Engineering Medicine, Texas A&M University, Houston, TX, USA

Abstract

Objective: Although bilateral brachial pressure measurement is routinely included in the diagnostic work-up of upper extremity ischemia, it is generally avoided in the presence of hemodialysis access due to fears of inducing access thrombosis. This study evaluated the safety of bilateral brachial pressure measurement in patients with clinical suspicion of dialysis-associated steal syndrome (DASS). Methods: Patients undergoing non-invasive testing for steal syndrome between September 2015 and December 2021 were included in this study. The diagnostic workup was performed by certified vascular sonographers in an outpatient vascular lab and consisted of bilateral brachial pressures, photoplethysmography, and duplex ultrasonography of the access. Interarm differential (IAD) was defined as systolic blood pressure (SBP) in the contralateral arm minus SBP in the access arm. The primary endpoint was immediate access thrombosis. Results: The study sample consisted of 331 subjects with a mean age of 61 ± 13 and a median access age of 9 months (3–31 months) with radiocephalic fistulas present in 29%. Many patients (68%) presented with paresthesia and 4% presented with tissue loss. The mean brachial systolic pressure was 152 ± 37 mmHg on the ipsilateral arm versus 143 ± 34 mmHg on the contralateral ( p-value <0.001), with an inter-arm differential (IAD) of −8.4 ± 19 mmHg. A total of 16 subjects (5%) presented a differential ⩾20 mmHg. A positive thrill was noted in all the accesses immediately following blood pressure measurement and no occurrence of access thrombosis was noted at 30 days. Proximal arterial revascularization interventions were performed in 11 cases (3%). Subjects who presented an IAD ⩾20 mmHg had lower ipsilateral digital-brachial index (0.39 ± 0.18 vs 0.68 ± 0.26; p = 0.037), a higher tendency of being referred for angiograms (37.5% vs 10.5%, p = 0.006), and more proximal arterial revascularization procedures (25.0% vs 2.2%, p = 0.001). Conclusion: Bilateral arm pressure measurement in the context of dialysis access-associated steal syndrome (DASS) appears safe and useful for identifying subjects whose symptoms are due to proximal arterial inflow disease. We therefore recommend this test be considered in the diagnostic algorithms of DASS.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3