Peripherally inserted central catheter with intracavitary electrocardiogram guidance: Malposition risk factors and indications for post-procedural control

Author:

Monard Céline12,Lefèvre Mathilde1,Subtil Fabien234,Piriou Vincent12,David Jean-Stephane12

Affiliation:

1. Département d’Anesthésie-Réanimation, Centre Hospitalier Lyon-Sud, Hospices Civils de Lyon, Lyon, France

2. Université Claude Bernard Lyon 1, Lyon, France

3. Service de Biostatistique, Hospices Civils de Lyon, Lyon, France

4. CNRS, UMR5558, Laboratoire de Biométrie et Biologie Evolutive, Villeurbanne, France

Abstract

Objectives: To confirm the feasibility of intracavitary electrocardiogram guidance to verify tip’s position during insertion of peripherally inserted central catheter and to identify clinical factors or intracavitary electrocardiogram patterns associated with aberrant tip’s position. Methods: A prospective study was conducted in our university hospital after authorization of the ethics committee. All patients addressed for peripherally inserted central catheter insertion were included and received the insertion using intracavitary electrocardiogram and electromagnetic guidance. Side of insertion and three electrocardiogram factors were collected: visualization of P-wave at baseline (sinusal rhythm), acquisition of the maximal P-wave and the negative deflection. All patients had a systematic post-procedural chest X-ray. One of the investigators assessed all chest X-ray, blinded to the results of intracavitary electrocardiogram, and confirmed whether the tip’s position on chest X-ray matched with the intracavitary electrocardiogram information or if the tip was malpositioned on chest X-ray (mismatch with intracavitary electrocardiogram or aberrant position). Factors associated with malposition were described. Results: From January 2015 to April 2015, 330 patients were eligible, 5 had an uninterpretable chest X-ray, and 14 were non-sinusal at baseline. Our main analysis population included 311 patients. We observed a mismatch between intracavitary electrocardiogram and chest X-ray estimate of the tip’s position in 3 cases (1%) and an aberrant tip’s position occurred in 3 cases (1%). Incidence of malposition was higher in the group of patients with non-sinusal rhythm (14%) and when the catheter was inserted on the left side (7%). Conclusion: This study confirmed the feasibility of intracavitary electrocardiogram for peripherally inserted central catheter positioning and the limits of chest X-ray. Insertion on left side may represent risk factor for aberrant position but our study lacked power to establish a statistical link.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3