Optical detection of infiltration during peripheral intravenous infusion in neonates

Author:

D’Andrea Vito1ORCID,Prontera Giorgia1,Carlino Riccardo1,Di Trani Helena1,Carlettini Ilaria1,Pittiruti Mauro2ORCID,Vento Giovanni1

Affiliation:

1. Neonatology Unit, Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy

2. Department of Surgery, Fondazione Policlinico Gemelli, Rome, Italy

Abstract

Background: Infiltration and extravasation are common complications during peripheral intravenous infusion in the neonatal intensive care unit, and diagnosis is usually clinical, by inspection and palpation. Delay in diagnosis due to poor surveillance or misinterpretation of clinical signs may carry serious damage to the tissues of the neonate. Recently, a novel technology based on optical detection of infiltration has become available. Methods: We have studied two groups of term and preterm infants receiving non-vesicant intravenous infusions by the peripheral route (24G short peripheral cannulas), and we evaluated the incidence of infiltration. In the first group, we have compared the clinical detection of infiltration versus the detection obtained by a novel optical device, blinding the alarms of the device. In the second group, the comparison was carried out without blinding the alarms. Results: Of the neonates included in this study, 60% were female, 86% had a gestational age <37 weeks (34 ± 2.5 weeks) and a mean birth weight of 2.08 ± 0.4 g. Total recorded monitoring time was 1318 h and average monitoring time for each short peripheral cannula was 26.4 h. The incidence of infiltration was 80%, most of them having a Millam score <2. The novel device showed an overall sensitivity of 88.9% in detecting infiltration. Specificity was 84.4%, as evaluated assuming as standard the clinical diagnosis. Interestingly, in cases of documented infiltration, the event was diagnosed by the optical device approximately 6 h before the clinical diagnosis. Conclusions: Continuous monitoring of the insertion site, as automatically ensured by this novel optical device, may play a complementary role in early detection of infiltration, even if the percentage of false positives and false negatives suggests that periodic clinical assessment by expert nurses cannot be omitted.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3