Effectiveness of mechanical recanalization for intraluminal occlusion of totally implantable venous access ports

Author:

Yang Woo Jin1,Song Myung Gyu1ORCID,Seo Tae-Seok1ORCID,Park Sung-Joon2ORCID

Affiliation:

1. Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea

2. Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, Gyeonggi-do, Korea

Abstract

Purpose: To evaluate if the mechanical injection of saline is effective in restoring patency of a totally implantable venous access port (TIVAP) with an intraluminal occlusion. Materials and methods: From January 2017 to June 2019, 64 cases of dysfunction of a TIVAP were referred to interventional radiology. Among these, 16 cases showed normal function of the TIVAP, 19 cases the showed the appearance of a fibroblastic sheath, and 29 cases showed intraluminal occlusion. Mechanical recanalization was performed for intraluminal occlusion of the TIVAP with an indeflator and a 20G non-coring needle. Linograms were performed in all recanalized cases. The success or failure of recanalization and the pressure of the indeflator were recorded. Linograms were evaluated for breakage or migration of catheters. Medical records were retrospectively reviewed. Results: Among the 29 intraluminal occlusion cases, 24 cases (82.7%) were recanalized by mechanical recanalization via an indeflator. The pressure of the indeflator ranged from 29 to 220 psi (median: 118 psi). Linograms revealed breakage of the catheter of the TIVAP in two failed cases. The median interval from implantation to dysfunction was 405 days (range: 43–1723 days). The median interval from last use to dysfunction was 8 days (mean: 15.4 days; range: 1–119 days). The median re-occlusion free period after successful mechanical recanalization was 100.5 days (range: 6–859 days). Conclusion: In the absence of an available thrombolytic agent, mechanical injection of saline was a tolerable alternative method for restoring occluded catheters and sustaining the function of catheters. Because breakage of the catheter can occur during mechanical recanalization of a TIVAP, a linogram should follow the procedure.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3