Factors Influencing Permanent Catheter Performance

Author:

Mandolfo S.1,Galli F.2,Costa S.3,Ravani P.4,Gaggia P.5,Imbasciati E.1

Affiliation:

1. Renal Units Lodi - Italy

2. FSM Pavia - Italy

3. Voghera - Italy

4. Cremona - Italy

5. Brescia - Italy

Abstract

Permanent dual lumen catheters (PDLC) provide an alternative vascular access in patients considered unsuitable for arteriovenous fistula, graft or peritoneal dialysis. However, the use of PDLC is often complicated by inadequate blood flow. The aim of this study was to identify catheter dysfunctions. We studied prospectively 57 chronic hemodialyzed patients, 73±11 years of age, with PDLC for 18±14 (1–48) months. Catheters were tunneled in silicone (MedComp Tesio n= 40) or in polyurethane (Permcath Quinton n = 11, GamCath Gambro n = 6) in left or right internal jugular (n = 49), in left or right subclavian (n = 3) and in right femoral vein (n = 5). We studied the blood viscosity indices (hematocrit, total protein, cholesterol and triglycerides), catheter intra-dialytic parameters (pre-pump and venous pressure), localization of the catheter tip (superior vena cava = SVC, right atrium = RA, inferior vena cava = IVC), blood pressure before and after hemodialysis during the 3 last dialyses, use of anticoagulant (ACT) or antiaggregant therapy (AAT) and previous infectious episodes. The mean blood flow was 269±37 ml/min (median 280 ml/min). The patients were divided according to the median value into groups I (Qb < 280, n = 28) and group II (Qb > 280, n =29). Results: Blood viscosity, patients’ mean arterial pressure and venous catheter line pressure did not differ between the two groups. Pre-pump pressure, at the start and at the end of treatment, was higher in group I. ACT, AAT and previous infectious episodes could not explain the low-performance. Blood flows of catheters localized in RA, SVC, and in IVC were respectively 287±20, 268±39, 244±27 ml/min. In the first case the Qb was significantly higher than IVC (p = 0.03) and SVC (p = 0.04). In conclusion, the most important factor influencing blood flow rates seems to be the position of the catheter tip in the venous system. The best blood flows were found in catheters with the tip localized in the right cardiac cavities, while PLDC placed in inferior vena cava showed lower blood flow.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3