Validation of the effectiveness of augmented reality-assisted vascular puncture: An experimental model

Author:

Morillas Pérez Jordi1ORCID,Mechó Meca Sandra2,Caballero Galindo Gerardo3,Miguel Pérez-Llano Jesús3

Affiliation:

1. Department of Intensive Care Medicine, Hospital of Barcelona, Barcelona, Spain

2. Department of Radiology, Hospital of Barcelona, Barcelona, Spain

3. TedCas Medical Systems, Pamplona, Spain

Abstract

Purpose: To demonstrate that the augmented reality-assisted puncture technique improves the efficacy of ultrasound-guided puncture to get central venous access (CVA), allows the image to be obtained without limitations, freeing the hands and keeping the gaze continuously on the working field, which contributes to improving the safety of the procedure. Material and methods: A gelatin mould with a latex surface and a chicken breast with silicone tubes inside were used to simulate vascular punctures. Images were obtained by an ultrasound scanner and post-processed with a specific software. A hologram was obtained and projected onto the previously delimited surface to be punctured. The variables related to image acquisition, the characteristics of the structure to be cannulated and the percentage of successes in the first attempt were analysed. Six operators were involved, using different ultrasound scanners. Efficiency was examined after the application of technical improvements in the process. Results: Seventy-six punctures were performed, guided by two different ultrasound scanners, divided into two groups: 37 with 33 successes (sigma = 3.52 with a process efficiency of 97.98%) and after technical improvements, 39 with 38 successes (sigma = 4.07 with a process efficiency of 99.4%). There are no significant differences among the operators (X2 p = 0.47) and between the ultrasound scanners (X2 p = 0.56). Conclusions: The augmented reality ultrasound-assisted CVA technique may be the next step in standardising the process of cannulation of vascular structures. This technique provides greater accuracy, greater comfort by freeing the hands and keeping the gaze on the working field, better ultrasound image quality, and eliminates variability between operators and sonographers.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3