Complications of Pediatric Mandibular Distraction Osteogenesis Hardware: A 10-Year Retrospective Analysis of the Food and Drug Administration Manufacturer and User Facility Device Experience Database

Author:

Jinka Sanjay K.A.1ORCID,Coombs Demetrius M.2,Murthy Ananth S.3

Affiliation:

1. Northeast Ohio Medical University, Rootstown, OH, USA

2. Cleveland Clinic, Cleveland, OH, USA

3. Akron Children’s Hospital, Akron, OH, USA

Abstract

Background: The United States Food and Drug Administration’s (FDA) Manufacturer and User Facility Device Experience (MAUDE) database provides access to device related adverse event reports. This database mandates national reporting of complications that lead to “death and serious injury” by manufacturers, importers, and device user facilities. This study used MAUDE to conduct post-market surveillance of pediatric mandibular distraction osteogenesis (MDO) hardware. Methods: A MAUDE database search with terms related to mandibular distraction was performed for report dates between October 1st, 2011, and October 1st, 2021. Duplicate reports, reports from literature reviews, and vague reports were removed. Manufacturers were contacted to establish which devices were pediatric-use-only. Adult-use and mixed-use devices were excluded. Each remaining report was manually reviewed/categorized to compile summative data. Results: Seventy pediatric-use-only device reports were identified. The damaged/non-functioning part of the device included the distractor itself (57.14% of reports), footplate(s) (37.14%), or screw(s) (5.71%). Intraoperative and postoperative complications made up 15.71% and 84.29% of reports, respectively. Twenty percent of complications occurred during the activation phase and 1.43% occurred during device removal. The most common report was failure of the device to advance (37.14% of total complications). Some form of operative treatment or explantation was performed for 51.43% and 34.29% of complications, respectively. External distractors and related hardware made up 8.6% of reports and the most common complication in this group was the screw backing out at 33.3% of all reports. Conclusions: The MAUDE database is a useful tool in evaluation of MDO device-related incidents. Most complications occur in the postoperative period, during the distraction phase, and often require device removal. The most common complication in external distractors was screws backing out. Mindful activation of the distractor, careful device/screw handling, technical improvement of the devices, and thorough preoperative planning may minimize these untoward events.

Publisher

SAGE Publications

Subject

Applied Mathematics,General Mathematics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3