Evaluating the safety and efficacy of epi-off corneal cross-linking in patients with thin corneas due to keratectasia

Author:

Nieuwsma Abigail12,Vander Zee Brandon L.3ORCID,Berdahl John P.4,Ibach Mitch4,Ferguson Tanner J.4,Terveen Daniel4

Affiliation:

1. University of Texas Health, San Antonio, TX, USA

2. University of South Dakota Sanford School of Medicine, Sioux Falls, SD, USA

3. University of South Dakota Sanford School of Medicine, 3140 Limekiln Avenue, Madison, WI, 53719, USA

4. Vance Thompson Vision, Sioux Falls, SD, USA

Abstract

Background: Corneal cross-linking (CXL) is a safe and effective procedure for slowing keratectasia progression in eyes with a corneal thickness of at least 400 µm. Limited research has evaluated the safety and efficacy of epi-off CXL in corneas thinner than 400 µm. Objective: To evaluate the safety and efficacy of CXL to slow keratectasia progression in eyes with <400 µm preoperative corneal thickness. Design: Retrospective chart review. Methods: This retrospective chart review included 37 eyes who underwent epi-off, iso-osmolar riboflavin corneal CXL with a preoperative thinnest point of the cornea <400 µm and had at least 6–12 months of follow-up. Preoperative and postoperative uncorrected visual acuity, best-corrected visual acuity (BCVA), thinnest point of the cornea, flat keratometry, steep keratometry, maximum keratometry (Kmax), need for penetrating keratoplasty, and cases of endothelial failure were recorded. Data were collected at baseline and months 3, 6, 9, and 12 post-CXL. Results: Following cross-linking, 18 eyes (47%) had improved BCVA, 13 (35%) had an unchanged BCVA, and 6 eyes (16%) had a worse BCVA ( p = 0.05). The mean postoperative BCVA was 20/81 (0.61 LogMAR) compared to 20/121 (0.78 LogMAR) preoperatively ( p = 0.06). Kmax decreased an average of 1.1 D at 3-month ( p = 0.53) and 3.4 D at the furthest follow-up ( p = 0.10). At the farthest follow-up, 22.7% of eyes had >1 D of Kmax steepening. No patients required keratoplasty and there were no cases of endothelial failure in the follow-up period. Conclusion: This research supports the safety and efficacy of epi-off, iso-osmolar CXL in eyes with <400 μm baseline corneal thickness with no patients requiring penetrating or endothelial keratoplasty, a trend toward improvement in BCVA, and Kmax flattening. In the future, prospective studies would be helpful to confirm these findings.

Funder

Glaukos

Publisher

SAGE Publications

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3