Effect of cycloplegic agents (1% cyclopentolate hydrochloride and 1% tropicamide) on anterior segment parameters

Author:

Duran Mustafa1,Cevher Selim2ORCID

Affiliation:

1. Department of Ophthalmology, Specialist of Ophthalmology, Minister of Health Hitit University Erol Olçok Education and Research Hospital, Çorum, Turkey

2. Department of Ophthalmology, Faculty of Medicine, Hitit University, Corum 019040, Turkey

Abstract

Background: Cycloplegic drops are commonly used in ophthalmology practice. Changes in anterior segment parameters may occur after cycloplegia. These changes can be evaluated with corneal topography. Objective: This study aimed to compare the effects of 1% cyclopentolate hydrochloride and 1% tropicamide on anterior segment parameters using the Sirius Scheimpflug imaging technique. Design: A cross-sectional study. Methods: One hundred twenty eyes of sixty healthy volunteers with spherical equivalent (SE) values of 0 to ±1 diopter (D) were studied. The right eye of each subject had instillation of cyclopentolate hydrochloride 1% (Group 1) and the left eye of each subject had instillation of tropicamide 1% (Group 2). SE, intraocular pressure, and corneal topography measurements were performed before and 40 min after instillation were compared. Results: In Group 1, SE, aqueous depth, anterior chamber depth, iridocorneal angle (ICA), anterior chamber volume (ACV), and pupil size (PS) values were significantly increased ( p < 0.001, p = 0.01, p < 0.001, p = 0.03, p < 0.001, and p < 0.001, respectively). In Group 2, SE, ICA, ACV, and PS were significantly increased ( p < 0.001 for all). Keratometric values (K1 and K2) and central corneal thickness changed insignificantly in both groups ( p > 0.05). The effects of the two administered agents on all parameters were similar ( p > 0.05). Conclusions: Cyclopentolate hydrochloride and tropicamide affected SE, ICA, ACV, and PS values significantly. These parameters are important in intraocular lens (IOL) power calculations. PS is also important in refractive surgery and cataract surgery with multifocal IOL implantation. Although there was an insignificant difference between the agents, the effects of tropicamide on the parameters were smaller than those of cyclopentolate.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3