Scheimpflug imaging for evaluation of intraocular lens position in modified flanged scleral fixated intraocular lens

Author:

Oli Avadhesh1ORCID,Yadav Anil1,Babu J. Ganesh1,Balakrishnan Divya2ORCID

Affiliation:

1. L V Prasad Eye Institute, Hyderabad, India

2. L V Prasad Eye Institute, Kallam Anji Reddy Campus, L. V. Prasad Marg, Banjara Hills, Hyderabad 500034, Telangana, India

Abstract

Background: Scleral fixation of intraocular lens (IOLs) is the most preferred technique for the management of aphakia and the techniques have evolved over the years. These methods have their advantages and disadvantages, however, the major concern being the position of the intraocular lens, its stability and complications. The final IOL position is the major determinant of the final visual acuity, and various imaging modalities have been used to quantify the IOL tilt. Objectives: Use of Scheimpflug imaging to evaluate the IOL tilt in modified flanged scleral-fixated intraocular lens (MFSIOL). Design: Retrospective chart review of 41 consecutive patients who underwent MFIOL. Methods: We conducted a retrospective chart review of 41 consecutive patients who underwent MFIOL. The baseline and final best-corrected visual acuity (BCVA), refractive error, and clinical examination findings were recorded. The vertical and horizontal tilts of the IOLs were calculated using the Scheimpflug image. The IOL tilt (in degrees) in the vertical and horizontal axes was the primary outcome and the BCVA, residual refractive error, intraocular pressure, and surgical complications were secondary outcome measures. Results: The mean baseline BCVA was logMAR 0.49, which improved to logMAR 0.356 ( p < .005) after the surgery. The mean IOL tilt in the vertical axis was 3.40° (range of 0.0°–8.5°, interquartile range: 1.21–5.66) and in the horizontal axis was 1.35° (range of 0.60°–4.620°, interquartile range: 0.44–1.86), respectively. There was no correlation between angle of IOL tilt and UCVA ( r = 0.089, p = 0.580), BCVA ( r = 0.109, p = 0.498), final spherical error ( r = 0.081, p = 0.615), cylindrical error ( r = 0.207, p = 0.195), axial length ( r = 0.105, p = 0.514), and IOL power ( r = –0.139, p = 0.388) Conclusion: Modified flanged IOL (MFIOL) is an alternative technique for intrascleral fixation of IOL resulting in good lens stability. The IOL tilt achieved by this technique is minimal and did not influence the final visual outcome or spectacle correction. Scheimpflug imaging is simple and non-invasive method to measure the IOL tilt. Plain Language Summary: Scheimpflug imaging for modified flanged scleral fixated lens position This study on 41 eyes was aimed to analyze the lens tilt using Scheimpflug imaging in cases of modified flanged scleral fixation of intraocular lens (MFSFIOL), which is a novel technique to minimize the complications and simplify the procedure. The intraocular lens (IOL) remained stable with an acceptable range of vertical and horizontal tilt. There was no significant effect of IOL tilt on the final best-corrected visual acuity (BCVA) or spectacle correction. Scheimpflug imaging is an accurate and non-invasive technique for assessment of lens position in the patients with intrascleral fixation of IOL.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3