Abstract

Background: Cardiac surgery has been associated with adverse ocular events. Off-pump coronary artery bypass graft surgery evades the systemic inflammatory response seen in extracorporeal circulation and is superior to on-pump surgery with regard to end-organ dysfunction and neurological outcomes. Objectives: To determine the effects of off-pump (without extracorporeal circulation) coronary artery bypass graft surgery on choroidal thickness, ganglion cell complex, and the retinal nerve fiber layer. Design: Prospective, longitudinal study. Methods: Patients who underwent off-pump surgery were examined preoperatively and postoperatively at 1 week and 6 weeks after surgery. Choroidal thickness, ganglion cell complex, and the retinal nerve fiber layer measurements were recorded, and the effects of off-pump coronary artery bypass on these parameters were assessed. Results: A total of 44 eyes of 44 patients were included in the study. There was a statistically significant increase in subfoveal choroidal thickness from 252.84 ± 56.24 µm preoperatively to 273.82 ± 39.76 µm at 1 week and 301.97 ± 44.83 µm at 6 weeks after off-pump coronary artery bypass graft surgery ( p = 0.044; p ⩽ 0.001). Ganglion cell complex and retinal nerve fiber measurements showed no significant difference compared to preoperative values. Conclusion: Off-pump coronary artery bypass graft surgery showed no negative effects on ganglion cell complex and retinal nerve fiber measurements. A significant increase in subfoveal choroidal thickness was seen after off-pump surgery, which might be advantageous in patients who are at high risk or have preexisting ocular diseases that are affected by the choroid.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3