BAY 81-8973, a full-length recombinant factor VIII for the treatment of hemophilia A: product review

Author:

Mahlangu Johnny N.1,Ahuja Sanjay P.2,Windyga Jerzy3,Church Nikki4,Shah Anita4,Schwartz Lawrence4

Affiliation:

1. Haemophilia Comprehensive Care Centre, School of Pathology, Faculty of Health Sciences, University of the Witwatersrand and National Health Laboratory Service, 7 York Road, Parktown, Johannesburg, South Africa

2. Division of Hematology and Oncology, Rainbow Babies and Children’s Hospital, Cleveland, OH, USA

3. Department of Disorders of Hemostasis and Internal Medicine, Institute of Haematology and Transfusion Medicine, Warsaw, Poland

4. Bayer, Whippany, NJ, USA

Abstract

BAY 81-8973 (Kovaltry®) is an unmodified, full-length recombinant factor VIII (rFVIII) approved for the prevention and treatment of bleeding episodes in patients with hemophilia A. The amino acid sequence for BAY 81-8973 is identical to that of sucrose-formulated rFVIII (rFVIII-FS; Kogenate® FS/KOGENATE®, Bayer), but the two products differ in their manufacturing approaches. The manufacture of BAY 81-8973 includes several modifications and enhancements, such as the introduction of the gene for human heat shock protein 70, a molecular chaperone protein that facilitates folding of proteins; no addition of human- or animal-derived proteins in the cell culture, purification process, or final formulation; and use of a 20-nm filter to remove any potential aggregates and pathogens. BAY 81-8973 was extensively studied in the LEOPOLD clinical development program, which enrolled participants of all age groups (children, adolescents, and adults) with severe hemophilia A. The pharmacokinetic profile of BAY 81-8973 was shown to be noninferior to, and for some variables more favorable than, rFVIII-FS and another commercial full-length rFVIII product. BAY 81-8973 was shown to be efficacious when used for prophylaxis, on-demand treatment, and perioperative hemostasis. The efficacious prophylaxis dose of BAY 81-8973 was approximately 20–40 IU/kg given two or three times per week, which achieved low annualized bleeding rates. Either the one-stage or the chromogenic assay provides accurate measurements for postinfusion monitoring of BAY 81-8973 levels, with no product-specific calibration standard needed. The incidence of treatment-related adverse events was ⩽7% across all LEOPOLD studies, and no previously treated patient developed anti-BAY 81-8973 inhibitors in the completed primary studies.

Funder

Bayer

Publisher

SAGE Publications

Subject

Hematology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3