Development and multi-center evaluation of a novel immunoadsorption method for anti-DFS70 antibodies

Author:

Bentow C1,Rosenblum R1,Correia P2,Karayev E2,Karayev D2,Williams D3,Kulczycka J4,Fritzler M J5,Mahler M1

Affiliation:

1. Department of Research, Inova Diagnostics, Inc., San Diego, USA

2. RDL Reference Laboratory, Los Angeles, USA

3. Immunology Department, Southampton General Hospital, Southampton, UK

4. Department of Clinical Immunology and Transplantation, Center of Laboratory Medicine, Medical University of Gdansk, Gdansk, Poland

5. Cumming School of Medicine, University of Calgary, Calgary, Canada

Abstract

Objective Antinuclear antibodies (ANA) represent a hallmark in the diagnosis of ANA-associated rheumatic diseases (AARD). However, anti-DFS70 antibodies are present in a higher portion of the healthy individuals (HI) than in patients with AARD. Consequently, we developed a novel, highly specific indirect immunofluorescence (IIF) method that blocks anti-DFS70 antibodies from binding to HEp-2 cells and to evaluate the method in a multi-center study. Methods A total of 18 samples from systemic lupus erythematosus patients (SLE, n = 7) and HI ( n = 11) were used for the initial development of the immunoadsorption method. For the multi-center evaluation, samples with a dense fine speckled (DFS) pattern ( n = 99) were collected at three different sites based on their established IIF screening procedure at the respective laboratories. Additionally, four characterized samples with established clinically relevant IIF patterns (centromere, nucleolar, speckled, homogeneous) were blended in five different ratios (10%, 25%, 50%, 75%, 90%) with a sample positive for anti-DFS70 antibodies, which by itself showed a dense fine speckled (DFS) IIF pattern. All samples were tested by IIF with NOVA Lite HEp-2 ANA and NOVA Lite HEp-2 Select on the NOVA View® instrument, and also tested by QUANTA Flash DFS70 chemiluminescent immunoassay (CIA) for confirmation of anti-DFS70 antibodies (Inova Diagnostics, San Diego, CA, USA). Results For the development of the immunoadsorption method, only 1/7 ANA-positive samples from SLE patients, but 8/10 ANA-positive samples from healthy individuals turned negative using the immunoadsorption. Subsequently, 73/99 (73.7%) of the DFS pattern samples were positive by CIA for anti-DFS70 antibodies showing a strong quantitative Spearman’s correlation (rho = 0.57 (95% CI, 0.39–0.71, p < 0.0001)) between light intensity units (LIU) measured by NOVA View and CIA. Intensities measured with NOVA Lite HEp-2 and NOVA Lite HEp-2 Select demonstrated significantly lower intensity values after inhibition with DFS70 antigen ( p < 0.0001). When samples were processed to mimic samples with mixed patterns (DFS + clinically relevant pattern), the new immunoadsorption method demonstrated that all clinically relevant patterns remained unchanged whereas the LIUs from NOVA View analysis significantly decreased after inhibition ( p < 0.0001). Conclusion The data showed that the NOVA Lite HEp-2 Select kit effectively inhibits anti-DFS70 antibody binding to its cellular target antigen.

Publisher

SAGE Publications

Subject

Rheumatology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3