Quality Control Procedures for Dose-Response Curve Generation Using Nanoliter Dispense Technologies

Author:

Quintero Catherine1,Rosenstein Craig1,Hughes Bethany1,Middleton Richard1,Kariv Ilona2

Affiliation:

1. Merck & Co., Inc., Merck Research Laboratories, Boston

2. Merck & Co., Inc., Merck Research Laboratories, Boston,

Abstract

With the advancement of high-throughput biomolecular screening techniques to the lead optimization stage, there is a critical need to quality control (QC) dose-response curves generated by robotic liquid handlers to ensure accurate affinity determinations. One challenge in evaluating the performance of liquid handlers is identifying and validating a robust method for testing dispense volumes across different instruments. Although traditional automated liquid handlers are still considered the standard platform in many laboratories, nanoliter dispensers are becoming more common and pose new challenges for routine quality control procedures. For example, standard gravimetric measurements are unreliable for testing the accuracy of nanoliter liquid dispenses. However, nanoliter dispensing technology allows for the conservation of compound, reduces compound carryover from well to well through discrete dispenses, and eliminates the need for intermediate compound dilution steps to achieve a low final DMSO assay concentration. Moreover, an intermediate dilution step in aqueous solution might result in compound precipitation at high concentrations. This study compared representative automation procedures done on a variety of liquid dispensers, including manual, traditional, and nanodispense volumes. The data confirmed the importance of establishing robust QC procedures for dose-response generation in addition to accuracy and precision determinations for each instrument, and they validated the use of nanoliter pipettors for dose-response testing. The results of this study also support the requirement for thorough mixing during serial compound dilutions prepared for high-throughput lead optimization strategies using traditional liquid handlers. ( Journal of Biomolecular Screening 2007:891-899)

Publisher

Elsevier BV

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3