Affiliation:
1. Department of Mechanical Engineering, University of Sheffield, Sheffield, UK
Abstract
A new leak detection method is proposed here which is based on the cepstrum of the cross-correlation of the pressure signals from two transducers. Computational simulations of leaks with different properties, size, position and shape, in a straight pipe and a T-Junction network were studied. The proposed method was successful in estimating leakages and the pipeline features with a high precision. For the results with a straight pipe, this method is considerably more accurate than using the cross-correlation leak detection method or the cepstrum method alone. However, the results obtained by cepstrum and cepstrum of cross-correlation for the T-Junction case were quite accurate, while cepstrum alone showed a slightly better precision.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Lost circulation detection method through transient pressure wave based on STA/LTA analysis;Geoenergy Science and Engineering;2024-09
2. Combined LDA-SVM approach for pipeline detection based on vibration signal;PROCEEDINGS OF THE 9TH INTERNATIONAL SYMPOSIUM ON INNOVATIVE BIOPRODUCTION INDONESIA ON BIOTECHNOLOGY AND BIOENGINEERING 2022: Strengthening Bioeconomy through Applied Biotechnology, Bioengineering, and Biodiversity;2023
3. Detection of Large-Scale Noisy Multi-Periodic Patterns with Discrete Double Fourier Transform. II. Study of Correlations Between Patterns;Fluctuation and Noise Letters;2020-09-15