Affiliation:
1. State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, PR China
Abstract
This paper investigates the expansion chamber attenuator utilized in marine hydraulic systems to determine the pulsation-reduction characteristics in hydraulic deck machinery applications. First, the background is briefly introduced. Next, the advantages and disadvantages of investigation methods borrowed from the aerodynamic field are discussed with regard to hydraulic use. Insertion loss is eventually selected to evaluate the performance of the attenuator. Finally, attenuator prototypes and a test rig that simulates an actual marine hydraulic system in a vessel are manufactured, and the experimental conditions are introduced in detail to calculate and measure the insertion loss. As indicated by the investigation conclusion, mathematic computation generally fits the test results. A better choice of length–diameter ratio ranges and other characteristics are discussed. This paper provides theoretical and experimental evidence regarding design expansion chamber attenuator use in hydraulic systems.
Reference18 articles.
1. Zeng XR. Hydraulic noise control, 1st ed. Harbin: Harbin Institute of Technology Press, 1988, pp. 112–220.
2. Fang DQ, Wang WQ. Noise control, 1st ed. Beijing: Beijing Publishing House Group, 1986, pp. 35–35.
3. A review on sonic crystal, its applications and numerical analysis techniques
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献