Strain measurement and error analysis in thermo-mechanical tensile tests of sheet metals for hot stamping applications

Author:

Shao Zhutao1,Li Nan2,Lin Jianguo1,Dean Trevor A3

Affiliation:

1. Department of Mechanical Engineering, Imperial College London, London, UK

2. Dyson School of Design Engineering, Imperial College London, London, UK

3. School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham, UK

Abstract

In order to conduct uniaxial tensile tests for hot stamping applications, tests are normally performed by using a Gleeble thermo-mechanical materials simulator so that rapid heating and cooling processes can be obtained. However, temperature gradients in a specimen tested on Gleeble are inevitable due to resistance heating principles and heat loss to grips and water-cooled jaws. In this research, a pair of purpose-built grips made of stainless steel with low thermal conductivity and significantly reduced contacting area for clamping, as well as a flat dog-bone specimen with maximised parallel length (80 mm) were designed, for the purpose of improving the temperature uniformity within the concerned gauge section area of the specimen. Uniaxial tensile tests on AA6082 were performed, after controlled heating and cooling processes, at constant deformation temperatures in the range of 400 ℃–500 ℃ and at constant strain rate in the range of 0.1–4/s, to simulate its hot stamping conditions. The digital image correlation system was adopted to enable strain distributions in specimens to be measured. The temperature distributions in specimens were investigated and an effective gauge length of 14 mm was specified accordingly to ensure temperature gradients less than 10 ℃ within it at all tested temperatures. True stress–true strain curves of AA6082 were obtained based on results of strain measurements along the defined effective gauge length and used to calibrate a set of advanced material model. Error analysis was carried out by using thermo-electrical and thermo-mechanical FE models on ABAQUS, in which the calibrated material constitutive equations were implemented via subroutines. The error of stress–strain curves of AA6082 measured based on the specified gauge length was investigated and quantified by analysing the distribution of axial strain and axial stress.

Publisher

SAGE Publications

Subject

Mechanical Engineering

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3