Finite element analysis and animal test verification of nitinol alloy iliac vein stent performance

Author:

Feng HQ1,Wang SB1ORCID,Wang YG2,Li XQ3,Mao YJ3,Wang XT4,Han QS1

Affiliation:

1. College of Mechanical Engineering, Inner Mongolia University of Technology, Hohhot, China

2. Suzhou Venmed Technology Co., Ltd, Suzhou, China

3. Department of Vascular Surgery, Second Affiliated Hospital of Soochow University, Suzhou, China

4. Department of Vascular Surgery, Anhui Provincial Hospital, Hefei, China

Abstract

The design and fatigue strength of a nitinol iliac vein stent (NIVS) proposed in this study are assessed using the finite element analysis method. The influence of stent diameter and different release scales on its strength, lifespan and biomechanical properties of the vein wall is analyzed for self-developed NIVS of three different diameters (12, 14 and 16mm) and length of 26mm, which were implanted into the corresponding iliac vein with different release scales (80% and 90%). The results obtained strongly indicate that with an increase in the release scale, the equivalent elastic strain, safety factors of fatigue strength, and equivalent stress of the vessel wall exhibit a downward trend, while the most stressed cross-section coincides with the arc of stent-connecting rods. The efficiency and safety of the above stents were verified by in vivo tests (with observation periods of 30, 90 and 180 days after operation) on ten lab pigs, which underwent NIVS implantation into the iliac veins, with observation of hemodynamics, stent deployment, presence/absence of thrombosis, and monitoring of stent lumen loss and its rate. During the animal test verification, the stent release was satisfactory, while the radiography revealed no obvious stent displacement at different time points. In addition, the patency rate of the stent was 100%. Except for the control group, where a small amount of old thrombus was found, other stents exhibited no thrombus; at the same time, there was no significant difference in the lumen loss rate of the stent at each time point. Therefore, the proposed nitinol NIVS samples demonstrated a good performance, accurate positioning, and release, in addition to the reduced risk of lateral iliac vein thrombosis.

Funder

the National Natural Science Foundation of China

the Natural Science Foundation of Inner Mongolia

Publisher

SAGE Publications

Subject

Mechanical Engineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献