Optimizing cranial implant and fixture design using different materials in cranioplasty

Author:

Jindal Prashant1ORCID,Chaitanya 1,Bharadwaja Shreerama Shiva Sai1,Rattra Shubham1,Pareek Deval1,Gupta Vipin2,Breedon Philip3ORCID,Reinwald Yvonne3,Juneja Mamta1ORCID

Affiliation:

1. University Institute of Engineering and Technology, Panjab University, Chandigarh, India

2. Government Medical College and Hospital, Chandigarh, India

3. School of Science and Technology, Department of Engineering, Nottingham Trent University, Nottingham, UK

Abstract

Cranial implants are used to secure intracranial structures, reconstruct the skull contour, normalise cerebral haemodynamic and repair cranial defects. Larger bone defects require intervention for repair from an implant made from autologous bone or other material. To repair such defects using implants, materials necessitate biocompatibility with the natural bone. Patient-specific implants are designed to repair specific cranial defects following standard procedures for implant design, fabrication and cranioplasty. Autologous bone, bone cement comprising hydroxyapatite, polymethyl methacrylate, medical-grade titanium alloy (Ti-6Al-4V) and polyether-ether-ketone, are widely used to fabricate patient-specific implant for repairing different types of bone defects. To optimize a patient-specific implant for shape, size and weight, it is essential to design the implant using 3D modelling and fabrication techniques. Effective attachment of an implant material with a defective skull is also influenced by the joints and fixture arrangements at the interface, these fixtures can be of various types, and materials have different joining procedures. In this study, a comparative analysis of different cranial implant materials (autologous bone, PMMA, polyether-ether-ketone and Ti-6Al-4V) attached to a defective skull with Ti-6Al-4V and polyether-ether-ketone fixture plates has been performed, using finite element analysis. Two types of fixture designs were used as square ‘X’ and linear shapes, which were fixed along with the interface between the implant and the skull. Four fixture plates were fixed symmetrically along the boundary to maximising stability. The findings suggested that all the implant materials were able to sustain extreme boundary conditions such as external loads of 1780 N and intracranial pressure of 15 mmHg without failures. Polyether-ether-ketone implants exhibited 13.5–35% lower von Mises stresses in comparison to autologous bone implants and the square ‘X’ fixture design provided higher stress-relieving results in comparison to Linear fixtures by nearly 18.4% for Ti-6Al-4V fixture material and 10.9% for polyether-ether-ketone fixture material, thereby, encouraging polyether-ether-ketone as an alternative to conventional cranial implant and fixture materials.

Funder

Ministry of Human Resource Development

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Materials Science

Reference42 articles.

1. Estimating the global incidence of traumatic brain injury

2. Verified Market Research. Global cranial implants market size by product, by material, by end-use, by geographic scope and forecast Report ID: 40159, June 2021.

3. Cranioplasty: Review of materials and techniques

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3