Validation of the SMH Equations for the Estimation of the Total Body Water Volume in Hemodialysis Patients

Author:

Noori Nazanin1ORCID,Sharma Parpia Arti2,Wald Ron23,Goldstein Marc B.2

Affiliation:

1. Department of Medicine, McGill University, Montreal, Quebec, Canada

2. Division of Nephrology, St. Michael’s Hospital, Toronto, Ontario, Canada

3. Li Ka Shing Knowledge Institute of St. Michael’s Hospital, Toronto, Ontario, Canada

Abstract

Background: Online dialysis clearance monitors typically provide an accurate value for Kt. A value for V (total body water [TBW]) is required to calculate Kt/V, the measure of the adequacy of the delivered dialysis in hemodialysis (HD) patients. Using bioimpedance spectroscopy (BIS), we previously developed 2 sex-specific equations for the estimation of the TBW, which we have chosen to name the St Michael’s Hospital (SMH) equations. Objective: The objective of this study was to validate the SMH equations in a second distinct population of patients. Design: Cross-sectional study. Setting: Single center hemodialysis unit at St Michael’s Hospital, a tertiary care teaching hospital, in Toronto, Canada. Patients: Eighty-one adult HD patients who had been receiving conventional maintenance HD for at least 3 months. Measurements: Anthropometric measurements including weight, height, and waist circumference were collected. TBW was measured by BIS using the Body Composition Monitor (Fresenius Medical Care, Bad Homburg, Germany). Methods: The Bland-Altman method to calculate the bias and limits of agreement and the difference plot analysis were used to evaluate the difference between the BIS-TBW and the TBW derived from our equations (SMH equation) in this validation cohort. Results: The TBW values based on our equations had a high correlation with BIS-TBW (correlation coefficients = 0.93, P values < .01, bias = 1.8 [95% CI: 1-2.6] liter). Application of SMH equations closely predicted Kt/V, based on BIS value, in all categories of waist circumference. Limitations: Small sample size, single-center, not including peritoneal dialysis patients. A larger and more heterogeneous sample with more patients at the extremes of body mass index would allow for more detailed sub-group analyses in different races and different anthropometric categories to better understand the performance of these equations in discrete sub-groups of patients. Conclusions: In maintenance HD patients, our previously derived equations to estimate the TBW using weight and waist circumference appear to be valid in a distinct patient population. Given the centrality of TBW to the calculation of small molecule clearance, the SMH equations may enhance the measurement of dialysis adequacy and inform practice.

Publisher

SAGE Publications

Subject

Nephrology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3